27

CLEAN FACE SURROUND MINIMUM ENCLOSURE CLEARANCES

**

FIGURE 82

FIGURE 81

NOTE:

**Installation requires a minimum 6 1/2" of non-combustible facing above the top of the fireplace.

OPTIONAL CLEAN FACE SURROUND INSTALLATION BGD36CF(G) ONLY

FIGURE 83

FIGURE 84

FIGURE 85

WAVE

CONVEX

CONCAVE

S36WN (BROWN)

S36CVN (BROWN)

S36CCN (BROWN)

S36WP (PEWTER)

S36CVP (PEWTER)

S36CCP (PEWTER)

Installation requires a minimum of 6 1/2" non-combustible facing material at the top of the fi replace. Refer to either Figure 86a or Figure 86b (depending on your installation) to ensure your fi replace has been installed with the proper requirements for this kit.

Whether installing to a fi nished fl oor or a hearth, a 3/8" clearance must be maintained at the bottom of the clean face surround kit. To obtain this clearance a fi replace riser is required.

FINISHED FLOOR INSTALLATION

When installing to a fi nished fl oor the fi replace riser must create a minimum clearance of 3 3/8" from the fi nished fl oor to the bottom of the fi replace.

 

 

 

 

 

 

FIGURE 86a

 

 

 

COMBUSTIBLE

 

 

 

STEEL

 

MATERIAL

 

STEEL

 

HEADER

 

NON-COMBUSTIBLE

HEADER

STAND-OFF

 

 

MATERIAL

STAND-OFF

 

 

 

 

 

 

 

6 1/2MINIMUM

 

 

 

CLEAN FACE SURROUND KIT

 

 

 

 

 

 

 

 

37 3/8

 

 

 

 

 

 

CLEAN FACE

 

FIREPLACE

 

 

 

SURROUND

 

RISER

 

 

 

 

KIT

 

 

FINISHED

3/8

3 3/8

FIREPLACE

3/8

3 3/8

FINISHED

FLOOR

CLEARANCE

 

RISER

CLEARANCE

 

FLOOR

 

 

 

 

 

 

W415-0661 / C / 02.20.08

Page 27
Image 27