Napoleon Fireplaces BGD36CFNTR Table Of Contents, Please Retain This Manual For Future Reference

Models: BGD42CFN BGD36CFNTR BGD36CFGN

1 48
Download 48 pages 29.33 Kb
Page 2
Image 2
TABLE OF CONTENTS

2

TABLE OF CONTENTS

PG 4-5

INTRODUCTION

 

Warranty

 

General Instructions

 

General Information

 

Care of Glass & Plated Parts

 

Unit Dimensions

 

Installation Overview

6-19

VENTING

 

Venting Lengths

 

Minimum Air Terminal Location Clearances

 

Typical Minimum and Maximum Vent Lengths

 

Special Vent Installations

 

Venting Application Flow Chart

 

Venting Specifications

 

BGD36CF(G) Pre-Installation Preparation

 

Removing the Valve Access Door

 

Door Operation

 

Rear Exit

 

Top Exit

19-29

INSTALLATION

 

Wall and Ceiling Protection

 

Horizontal Installation

 

Adjustable Firestop Installation

 

Vertical Installation

 

Using Flexible Vent Components

 

Using Rigid Vent Components

 

Restricting Vertical Vents (BGD42CF ONLY)

 

Gas Installation

 

Optional wall switch installation excluding BGD36CFG

 

Mobile Home Installation

 

Framing

 

Installing Standoffs

 

BGD36CF(G) Minimum Mantel and Enclosure Clearances

 

Clean Face Surround Minimum Enclosure Clearances

 

Optional Clean Face Surround Installation BGD36CF(G) only

 

Finished Floor Installation

 

Hearth Installation

 

Optional Clean Face Trim Kit Installation

 

BGD42CF Minimum Mantel and Enclosure Clearances

30

BGD36CF FINISHING

Log Placement

Glass/Door Replacement

30-31

BGD42CF FINISHING

 

Door Installation / Removal

 

Removing Valve Access Door

 

Glass/Door Replacement

 

Door Trim

 

Grate Installation

 

Log Placement

32

COMMON FINISHING

 

Glowing Embers

 

Charcoal Embers

 

Vermiculite

 

Charcoal Lumps (BGD42CF Only)

 

Logo Placement

32

BGD36CFG FINISHING

 

Glass Burner Installation

 

BGD36CFG bulb replacement

 

BGD36CFG lens assembly replacement

33

OPTIONAL BLOWER INSTALLATION

BGD36CF Accessing the Blower

BGD42CF Accessing the Blower

Installing the Blower

34OPTIONAL FAN INSTALLATION

GD36 THERMOSTATIC SENSOR CONTROL

35BGD36CFG BURNER SWITCH/WIRING DIAGRAM

36BGD36CFG LIGHT SWITCH/WIRING DIAGRAM

37RECEPTACLE WIRING DIAGRAM

38OPERATION BGD36CF AND BGD42CF

Operating Instructions

Maintenance

39OPERATION / MAINTENANCE BGD36CFG 40-41 ADJUSTMENTS

Pilot Burner Adjustment

Venturi Adjustment

BGD36CFG Venturi Adjustment

Flame Adjustment

42-44 COMMON REPLACEMENTS BGD36CF(G) REPLACEMENTS BGD42CF REPLACEMENTS

45-48 TROUBLE SHOOTING GUIDE

47SERVICE HISTORY

48NOTES

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

!WARNING

Do not burn wood or other materials in this fireplace.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace.

Clothing or other flammable material should not be placed on or near the fireplace.

Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.

Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.

Even after the fireplace is out, the glass and/or screen will remain hot for an extended period of time.

Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the floor.

Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.

It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace and venting system are kept clean. The fireplace and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this fireplace be modified.

This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the fireplace glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

Pressure relief doors must be kept closed while the fireplace is operating to prevent exhaust fumes containing carbon monox- ide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause the surrounding combustible materials to overheat and catch fire.

Only doors / optional fronts certified with the unit are to be installed on the appliance.

NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN.

W415-0661 / C / 02.20.08

Page 2
Image 2
Napoleon Fireplaces BGD36CFNTR manual Table Of Contents, Please Retain This Manual For Future Reference, Introduction, 6-19