BGD42CF HORIZONTAL TERMINATION

when (HT) < (VT)

90°

Simple venting confi guration (only

 

 

one 45º and 90° elbow)

 

 

FIGURE 34

45°

REQUIRED

VERTICAL RISE IN FEET (VT)

CALCULATED HORIZONTAL VENT RUN

PLUS OFFSETS IN FEET (HT)

The shaded area within the lines represents acceptable values for HT and VT .

when (HT) > (VT) Simple venting con-

guration (only one 45º and 90° elbow)

FIGURE 36

See graph to deter- mine the required vertical rise VT for the required horizontal run HT.

REQUIRED VER-

TICAL RISE IN

INCHES VT

The shaded area within the lines represents acceptable values for HT and VT .

HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (HT)

For vent confi gurations requiring more than one 45º and 90° elbow, the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

Example 1:

90°

H2

 

V1

 

FIGURE 35

 

45°

 

H1

 

V1 = 8 ft

 

VT V1= 8 ft

 

H1 = 2.5 ft

 

H2 = 2 ft

 

HR = H1 + H2 = 2.5 + 2 = 4.5 ft

 

HO = .03 (one 45° elbows + two 90° elbows - 135°)

 

= .03(225 - 135°) = 2.7 ft

 

HT = HR + HO = 4.5 + 2.7 = 7.2 ft

 

HT + VT = 7.2 + 8 = 15.2 ft

 

Formula 1: HT < VT

 

7.2< 8

Formula 2: HT + VT < 40 feet 15.2 < 40

Since both formulas are met, this vent confi guration is acceptable.

For vent confi gurations requiring more than one 45º and one 90° elbow the following formulas apply:

Formula 1: HT < 4.2 VT

 

 

 

 

Formula 2: HT + VT < 24.75 feet

90°

 

Example 2:

H1

H4

90°

90° H3

V2

V1 90° H2

45°

FIGURE 37

V1 = 4 ft

V2 = 1.5 ft

VT = V1 + V2 = 4 + 1.5 = 5.5 ft

H1 = 2 ft

H2 = 1 ft

H3 = 1 ft

H4 = 1.5 ft

HR = H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1.5 = 5.5 ft

HO = .03 (one 45° elbow + four 90° elbows - 135°)

= .03(405 - 135) = 8.1 ft

 

HT = HR + HO = 5.5

+ 8.1

= 13.6 ft

HT + VT

= 13.6 +

5.5 =

19.1 ft

Formula 1:

HT < 4.2VT

4.2VT = 4.2 x 5.5 = 23.1 ft 13.6 < 16.8

Formula 2: HT + VT < 24.75 feet

19.1 < 24.75

Since both formulas are met, this vent confi guration is accept- able.