FOR YOUR SAFETY READ BEFORE OPERATING

! WARNING

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

 

A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE

REPLACE ANY PART OF THE CONTROL SYSTEM AND

 

 

WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY

ANY GAS CONTROL WHICH HAS BEEN UNDER

 

 

TO LIGHT BY HAND.

 

WATER.

 

 

 

 

 

B. BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE

WHAT TO DO IF YOU SMELL GAS:

 

 

AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE SOME

• TURN OFF ALL GAS TO THE FIREPLACE.

 

 

GAS IS HEAVIER THAN AIR AND WILL SETTLE ON THE

• OPEN WINDOWS.

 

 

FLOOR.

 

• DO NOT TRY TO LIGHT ANY APPLIANCE.

 

C. USE ONLY YOUR HAND TO TURN THE GAS CONTROL

 

• DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT

 

 

KNOB. NEVER USE TOOLS. IF THE KNOB WILL NOT TURN

USE ANY PHONE IN YOUR BUILDING.

 

 

BY HAND, DO NOT TRY TO REPAIR IT. CALL A QUALIFIED

• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A

 

 

SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR

NEIGHBOUR'S PHONE FOLLOW THE (GAS

 

 

MAY RESULT IN A FIRE OR EXPLOSION.

 

SUPPLIER'S) INSTRUCTIONS.

 

D. DO NOT USE THIS FIREPLACE IF ANY PART HAS BEEN

• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL

 

 

UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE

THE FIRE DEPARTMENT.

 

 

TECHNICIAN TO INSPECT THE FIREPLACE AND

 

 

 

 

 

 

 

 

 

 

 

OPERATING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

STOP! READ THE ABOVE SAFETY INFORMATION ON

NEXT STEP.

 

 

 

 

 

 

THIS LABEL.

 

8. CLOSE THE GLASS DOOR.

 

2.

TURN REMOTE WALL SWITCH TO OFF POSITION.

 

9. TURN MANUAL SHUTOFF VALVE COUNTER-

 

3.

TURN OFF ALL ELECTRIC POWER TO THE FIREPLACE

CLOCKWISE

TO ON.

 

 

AND REMOVE BATTERIES.

 

10. TURN ON ALL ELECTRIC POWER TO THE FIREPLACE

 

4.

THIS FIREPLACE IS EQUIPPED WITH AN IGNITION

 

AND RE-INSTALL BATTERIES.

 

 

DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO

11. TURN ON REMOTE WALL SWITCH TO ON POSITION.

 

 

NOT TRY TO LIGHT THE PILOT BY HAND.

 

12. IF FIREPLACE WILL NOT OPERATE, FOLLOW

 

5.

TURN MANUAL SHUTOFF VALVE CLOCKWISE

TO

INSTRUCTIONS "TO TURN OFF GAS" AND CALL YOUR

 

 

OFF.

 

SERVICE TECHNICIAN OR GAS SUPPLIER.

 

6.

OPEN THE GLASS DOOR.

 

 

 

 

 

Manual Shut-off Valve

 

7.

WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. IF

 

 

 

 

 

 

Shown in “OFF”

 

 

YOU SMELL GAS INCLUDING NEAR THE FLOOR, STOP!

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOLLOW "B" IN THE ABOVE SAFETY INFORMATION ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS LABEL. IF YOU DON'T SMELL GAS GO TO THE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO TURN OFF GAS

1.TURN OFF REMOTE WALL SWITCH TO THE FIREPLACE.

2.TURN OFF ALL ELECTRICAL POWER TO THE FIREPLACE IF SERVICE IS TO BE PERFORMED.

3.TURN MANUAL SHUTOFF VALVE CLOCKWISE FOR YOUR SAFETY READ BEFORE OPERATINGTO OFF. DO NOT FORCE.

MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This fi replace and its venting system should be inspected before use and at least annually by a qualifi ed service person. The fi replace area must be kept clear and free of combustible materials, gasoline or other fl ammable vapours and liquids. The fl ow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter

opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4.Check to see that the pilot fl ame is large enough to engulf the thermocouple and thermopile and reaches toward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all open- ings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon® dealer / distributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

W415-0661 / C / 02.20.08