6.0INSTALLATION GUIDE

On installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be used must be adhered to. Otherwise the refrigerator must be installed as described in these instructions. In some OEM appli- cations it may not be possible for these instructions to be followed exactly. In this case an authorised Dometic representative may issue supplementary instruction

In Europe, for example, gas appliances, cable laying, installation of gas cylinders, as well as approval and checking for leaks must comply with EN 1949 for liquid gas units in vehicles.

6.1Installation

The appliance and its fume extraction shall be installed in such a way as to be acces- sible for servicing at all times and must be capable of easy removal and installation. The appliance may only be installed by authorised personnel.

Installation and connection of the appliance must comply with the latest technical regulations, as follows:

￿The electrical installation must comply with national regulations.

￿Technical regulations EN 60335-1, EN 60335-2-24, EN 1648-1 , EN 1648-2

￿The gas installation must comply with national regulations.

￿Technical regulations EN 1949

￿Technical regulations EN 732

￿Local and building control department requirements

￿The appliance shall be installed in such a way that it is shielded from excessive heat radiation.

Excessive heat impairs performance and raises the energy consumption of the refrigerator.

Any installation that is not carried out by qualified persons will jeo- pardize the manufacturer's guarantee.

6.1.1Side installation

If the appliance is installed on the same side of the vehicle as the entrance

door, it is desirable that the door does not cover the refrigerator’s vents. If this cannot be avoided there must be a gap of at least 25mm between the door and the vents.

6.1.2Rear installation

If the refrigerator is mounted at the rear of the vehicle you must ensure the lower grille is not covered by the bumper or rear lights. This would be prevent the air from circula- ting properly and cause problems in warm weather.

Air vent grille not

blocked: OK!

An installation that is not carried out by qualified persons causes a reduction in the cooling capacity and will jeopardize the manufactur- er's guarantee.

18

Page 18
Image 18
Dometic RM 7605 L, RM 7651 L, RM 7655 L, RM 7601 L Installation, Side installation, Rear installation