6.9.6Wiring diagram

Wiring diagram for RM 76x1 L

permanently connection DC C

D

Burner ionisation

Control electrode

Device

ignition plug

ignition unit

Ground

gas burner

terminal block heating element DC

GasB

Switch

Valve

 

Frame

 

Heating

A

 

Reed contacts (sensor switching)

 

 

heating element DC

 

 

 

temp. sensor

 

 

 

heating element AC

 

 

 

lighting DC

 

 

 

 

mains

Power Module

 

 

 

 

Ground

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connections:Colours:

A = Ground heating element DC B = Plus heating element DC C = Ground electronics

D = Plus electronics

schwarz = black violett = violet braun = brown weiss = white grün = green gelb = yellow rot = red

27

Page 27
Image 27
Dometic RM 7601 L, RM 7651 L, RM 7655 L, RM 7605 L installation instructions Wiring diagram for RM 76x1 L