￿Inflamable material should not be in immediate proximity to the burner.

￿The gas connection to the appliance is effected by means of a suitable coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).

The gas connection may only be carried out by a qualified personnel.

Following proper installation, a testing for leakage and a flame test must be car- ried out by *qualified personnel in compliance with EN 1949 .

A certificate of testing must be issued.

* qualified personnel

Qualified personnel are accredited experts who are able, by virtue of their training and knowledge, to vouch for the correct implementation of the leakage test.

ATTENTION

15 Nm

 

20 Nm

max

 

max

 

 

 

SW 14 SW 17

C

The refrigerator must be equipped with a gas cock

(C) in the supply line to allow the supply to be disconnected. Such a cut-out device must be readily accessible to the user.

Gas-pressure

Category

I3P(30)

I 3P(37)

I3P(50)

 

I3+

I3B/P(50)

I3B/P(30)

mbar

30

37

50

28-37

30-37

50

30

 

 

 

 

 

 

 

 

BE

 

 

 

X

 

 

 

DK

 

 

 

 

 

 

X

DE

 

 

 

 

 

X

X

FI

 

 

 

 

 

 

X

FR

 

 

 

X

 

 

 

GR

 

 

 

 

X

 

X

IE

 

X

 

X

 

 

 

IS

 

 

 

 

 

 

X

IT

 

 

 

X

 

 

 

LU

X

 

 

 

 

 

X

NL

X

 

 

 

 

 

X

NO

 

 

 

 

 

 

X

AT

 

 

 

 

 

X

X

PT

 

X

 

 

X

 

 

SE

 

 

 

 

 

 

X

CH

 

 

 

X

 

 

X

ES

 

 

 

X

 

 

 

UK

 

X

 

X

 

 

X