6.7Connections for gas / electrical installation

Terminal block 12VDC permanent connection

Terminal block

12VDC heating element

Gas valve

connection gas supply

Terminal block

12V DC conn. power module and D+ input

6.8Gas installation

￿The rules in point 6.1 must be adhered to.

￿When running on gas, these appliances are intended exclusively to use liquid gas (propane/butane) - under no circumstances should town gas or natural gas be used (EN 27418).

￿A fixed, pre-set pressure regulator complying with EN 12864 must be connected to the liquid gas cylinder.

￿The pressure regulator must concur with the operating pressure specified on the data plate of the appliance. The operating pressure corresponds to the standard pressure of the country of specification (EN 1949, EN 732).

￿Only one connection pressure is permissible for any one vehicle. A plate showing the permanent, clearly legible notice must be displayed in full view at the point where the gas cylinder is installed.

￿The gas connection to the appliance must be installed securely and at

zero potential using tube connectors and must be securely connected to the vehicle (a hose connection is not permissible) (EN 1949) .

23

Page 23
Image 23