6.2Draught-free installation

The refrigerator must be sealed in accordance with EN 1949.

Illustrated below is a typical approved method of sealing.

Proposal :

 

 

 

 

 

 

Using the Installation Sealing Kit from Dometic

 

 

 

 

 

FIG. 1

 

B

 

 

 

 

 

 

 

(available from Dometic)

 

 

 

 

 

 

 

 

 

Insert lipped seals (A) into the installation recesses

 

 

 

 

 

 

 

 

 

 

 

 

at the bottom and at each side (FIG 1, 2, 3).

 

 

 

 

 

 

Insert deflector plate (B), fitted with a lipped seal (A)

 

 

 

 

 

 

 

 

 

 

 

 

of heavy-duty, non- flammable material, into the

 

 

 

 

 

 

installation recess (see Fig. 4).

 

 

 

 

 

 

Insert deflector plate (B) in such a way that the hot

 

 

 

 

 

 

air escapes through the air vent grille into the open

 

 

 

 

 

 

air. Affix the discharge plate to the caravan wall, not

 

 

 

A

 

 

to the refrigerator !

 

 

 

 

 

 

In addition, discharge plate (B) with its lipped seal

 

 

 

 

 

 

(A)must seal the refrigerator off from the living area (see FIG. 1,4).

Ensure that the refrigerator is installed level in the recess.

B

A

A

FIG. 2

FIG. 3

FIG. 4

Finally, push the refrigerator into the recess from the front.

This installation option facilitates the removal and installation of the appliance for servicing.

Comment:

Other methods of sealing may be approved. However the chosen method must pre- vent draughts entering the living space of the motorhome. Failure to seal correctly will allow warm air to collect around the refrigerator and its performance will be affected. If the cavity between the vehicle’s wall and the refrigerator is sealed so that fumes cannot penetrate the living area it is possible to vent the flue gas directly through the upper grille

Do not use any kind of aluminium flue pipe (e.g. T-piece) to lead the flue gas out.

Deviations shall require the consent of the manufacturer.