To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

SETUPS

5.1 Digital - 192 kHz

This is a 5.1 digital setup at 192kHz with Bass Management as an option. The setup requires three Master monitors with the optional Digital I/O card installed, two Slaves and one Sub.

• Left monitor is set as System Controller by leaving out the TC Link button on the rear panel.

• - Left monitor receives Left and Right Front channels. - Center monitor receives Center channel and Sub.

- Left Rear monitor receives LS and RS channels.

• The Sub receives signal via TC LINK RJ-45 connections from the Center Master monitor.

• Clock MUST be sent on the AES connection feeding Center/LFE channels (or on BNC).

• With Bass-management “off” only the LFE signal is fed to the Sub.

• With Bass-management activated, Low Frequency information below the set Cross-over frequency from the 5 main channels is extracted and distributed to the Sub where it is summed with the LFE channel.

The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.

6.1 Digital - 192 kHz

This is a 6.1 digital setup with Bass Management as an option. The setup requires four Master monitors with the optional Digital I/O Card installed, two Slave monitors (or Masters set as Slave) and one Sub.

• Left monitor is set as System Controller by leaving out the TC Link button on the rear panel.

• - Left monitor receives both Left and Right Input signals. - Right monitor receives signal via the TC LINK cable.

- Left Surround, receives both Left and Right surround signals.

- Right Surround, receives signal via the TC LINK cable.

-Center receives both Center and Sub signals.

-The Sub receives signal via the TC LINK cable.

- Center Surround receives Center Surround channel.

• Clock MUST be sent on the AES connection feeding Center/LFE channels (or on BNC).

With Bass-management “off” only the LFE signal is fed to the Sub.

With Bass-management activated, Low Frequency information below the set Cross-over frequency from the 6 main channels is extracted and distributed to the Sub where it is summed with the LFE channel.

The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.