20
•Never adjust blade angle of HCA while standing
•Only adjust cutting angle with HCA resting flat on the ground, with the engine stop switch in the "STOP" position.
•Adjust cutting angle by moving locking lever (A) up. Depress blade indexing lever (B) and change blade angle with rear cutter assembly handle. Release indexing lever into notch. Move locking lever down to completely engage internal gears.
IMPORTANT
Locking lever (A) does not secure gear box angle setting. Moving lever in the down position reduces internal play in the gear box. Do not over tighten castle nut (C) to insure gear box angle setting tightness because damage to internal gears will occur. If the lever is loose or very tight, adjust nut (C) for snug 90° movement.
A C
B
NEW
PHOTO
WARNING DANGER
Blades should not move at idle. If blades move, readjust carburetor according to Carburetor Adjustment instructions in the manual or see your ECHO dealer, otherwise serious personal injury may result.
1.Stop Switch - Start/Run.
Move Stop Switch button away from the STOP position.
2.Close Choke - Cold Start.
Move choke (B) to "Cold Start" position.
3.Primer - Pump Bulb.
Pump primer bulb (C) 10 times. Fuel will be visible and flow freely in the “Clear” fuel return line.
B
WARNING DANGER
Inspect starting area for hazards such as rocks, glass, debris etc. which could be contacted by the cutting blades when starting. Keep helpers and bystanders at least 15 M (50 ft.) from starting area, otherwise serious personal injury may result.
CHCA-2400
D
B
C
D