UCLI72-4 Quad Charger

The UCLI72-4 Quad Charger is designed to charge up to four QL Series battery packs simultaneously. Batteries must be removed from the printer to be charged in the Quad Charger.

1.Ensure that the charger has been installed properly per the Quad Charger instruction manual. Ensure that the power indicator on the front panel is on.

2.Remove any protective shrink-wrap and labels from all battery packs prior to use. Plug a battery pack into any one of the four charging bays as shown in Figure 4, noting the orien- tation of the battery pack. Slide the battery pack into the charging bay until it stops. Then rock the battery pack back until it snaps into place. The amber indicator directly under the battery being charged will turn on if the battery is properly in- serted.

The indicators under the battery will allow you to monitor the charging process per the table below:

Amber

Green

Battery Status

On

Off

Charging

On

Flashing

80% charged (O.K. to use)

Off

On

Completely Charged

Flashing

Off

Fault

 

 

 

Note: A fault condition is caused by a problem with the battery. The charger may indicate a fault because the battery is too hot or cold to charge reliably. Try to charge the battery again when it returns to the room’s ambient temperature. If the Amber indicator starts flashing on the second attempt, the battery should be discarded.

Quad Charger Cycle Times :

Battery Status

QL 220/320

QL 420

Battery 80% Charged

1.25 Hrs.

2.5 Hrs.

Battery Fully Charged

2.5 Hrs.

5 Hrs.

NOTE: These times are for completely discharged batteries.

continued

13