QL 420 Cleaning
Area  | Method  | Interval  | |||
  | Use the supplied cleaning pen or 70%  | 
  | |||
Printhead  | isopropyl alcohol on a cotton swab to  | 
  | |||
(Figure 21)  | clean the print elements from end to end  | After every five  | |||
  | (the print elements are located in the thin  | ||||
  | gray line on the printhead).  | rolls of media  | |||
  | 
  | 
  | 
  | (or more often,  | |
  | 
  | 
  | 
  | if needed)  | |
  | Rotate the platen roller and clean it  | ||||
  | Linerless media  | ||||
Platen  | thoroughly with the cleaning pen or 70%  | requires more  | |||
isopropyl alcohol and a cotton swab.  | frequent  | ||||
Roller  | 
  | 
  | 
  | cleaning  | |
  | 
  | 
  | |||
(Figure 21)  | Units with linerless platens: Rotate  | 
  | |||
  | platen & clean bearing points only. Avoid  | 
  | |||
  | use of alcohol on the surface of linerless  | 
  | |||
  | platens!  | 
  | |||
  | 
  | 
  | |||
Peel bar  | Clean thoroughly with the cleaning pen or  | As needed  | |||
(Figure 21)  | 70% isopropyl alcohol and a cotton swab.  | ||||
  | |||||
  | 
  | 
  | 
  | 
  | |
Scraper  | Clean thoroughly with the cleaning pen  | After every five  | |||
(Linerless units  | rolls of media  | ||||
or 70% isopropyl alcohol and a cotton  | |||||
only) Figure 21  | (or more often,  | ||||
  | 
  | 
  | |||
  | 
  | 
  | 
  | if needed)  | |
Tear bar  | Clean thoroughly with the  | 
  | |||
cleaning pen or 70% isopropyl  | 
  | ||||
(Figure 21)  | 
  | ||||
alcohol and a cotton swab.  | 
  | ||||
  | 
  | ||||
  | 
  | 
  | 
  | As needed  | |
Exterior  | |||||
  | |||||
  | 
  | 
  | |||
  | Brush/air blow. Ensure the Bar Sensor, Gap  | 
  | |||
  | Sensor and Label Present Sensor windows are  | 
  | |||
Interior  | free of dust.  | 
  | |||
  | 
  | 
  | 
  | ||
(Figure  | Units with linerless platens:  | After every five  | |||
21)  | |||||
Clean inside surfaces of edge guides & media  | |||||
rolls of media  | |||||
  | |||||
  | rollers with the supplied cleaning pen or 70%  | ||||
  | (or more often,  | ||||
  | isopropyl alcohol on a cotton swab.  | ||||
  | if needed)  | ||||
  | 
  | 
  | 
  | ||
  | 
  | 
  | |||
  | Clean thoroughly with the cleaning pen  | 
  | |||
  | or 70% isopropyl alcohol and a cotton  | After every five  | |||
  | swab.  | ||||
Media Rollers  | 
  | 
  | 
  | rolls of media  | |
  | 
  | 
  | |||
(Figure 18)  | Units with linerless platens: Rotate media  | (or more often,  | |||
  | rollers & clean bearing points only. Avoid  | if needed)  | |||
  | use of alcohol on the surface of the  | 
  | |||
  | media rollers!  | 
  | |||
  | 
  | 50  | 
  | 
  | |
  | QL Series User Guide  | 
  | |||