BASIC OPERATION

 

TURNING OFF THE PROJECTOR

1

Press the POWER ON-OFF button on the top control or on

 

 

 

 

 

 

 

 

 

the remote control, and a message "Power off?" appears on

 

 

 

 

 

the screen.

 

 

 

 

2

Press the POWER ON-OFF button again to turn off the

 

 

 

 

 

 

 

 

projector. The LAMP Indicator lights bright and READY

 

 

 

 

 

 

 

 

 

 

Indicator turns off. After projector is turned off, Cooling Fans

 

 

 

 

 

operate (for 90 seconds). During this "Cooling Down" period,

 

 

 

 

 

this appliance cannot be turned on.

 

 

 

 

 

The message disappears after 4 seconds.

 

 

3

When the projector has cooled down, READY Indicator lights

 

GREEN again and you can turn projector on. After cooling

down completely, disconnect AC Power Cord.

TO MAINTAIN THE LIFE OF LAMP, ONCE YOU TURN

PROJECTOR ON, WAIT AT LEAST 5 MINUTES

BEFORE TURNING IT OFF.

DO NOT DISCONNECT AC POWER CORD WHILE

COOLING FANS ARE RUNNING OR BEFORE READY

INDICATOR LIGHTS GREEN AGAIN. OTHERWISE IT

WILL RESULT IN SHORTENING LAMP LIFE.

NOTE;

The projector cannot be turned on during the cooling period with the READY indicator turned off. You can turn it on again after the READY indicator GREEN again.

When the On start function is on, this projector is turned on automati- cally by connecting the AC power cord to an AC outlet. (See page 40 for the On start function.)

Do not operate the projector continuously without rest. Continuous use may result in shortening the lamp life. Turn off the projector and give it a rest about an hour in every 24 hours.

This projector monitors internal temperature and automatically controls the running speed of the cooling fans.

If the WARNING TEMP indicator flashes red, see “WARNING TEMP INDICATOR ” on page 44.