5. LAMP INSTALLATION INSTRUCTIONS

Installing or replacing the lamp

Only install the lamp with the device unplugged from the mains.

The lamp has to be replaced when it is damaged or deformed.

Before replacing the lamp be sure the unit has ample time to cool, to avoid injury to yourself never touch the lamp when it is hot.

During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal.

Do not install lamps with a higher wattage. They generate higher temperatures than which the device was designed for.

For the installation, you need one MSD250/2 GY9.5 lamp;

Procedure:

1.Remove the two thumbscrews labeled “A” and “B” on the rear housing of the head.

2.Gently pull the lamp/socket assembly to access the lamp.

3.Gently remove the old lamp by grasping it by the ceramic base.

4.Carefully insert the new lamp into the socket. Please remember there is only one way to insert the lamp. Once the lamp has be inserted into the socket, gently slide the socket assembly back into place and fasten the two thumb screws.