Focus Spot 250R™

05Er - Color-wheel error:

The color wheel is not located in the default position after start-up or after a reset command.

This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).

06Er - Rotating gobo-wheel error:

The gobo-wheel is not located in the default position after start-up or after a reset command.

This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).

07Er - Rotating gobo indexing error:

The gobo is not located in the default position after start-up or after a reset command.

This message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).

©Elation Professional®