at a time until the light is evenly distributed.
4. If the light is brighter around the edge than it is in the center, or if light output is low,
the lamp is too far back in the reflector. "Push” the lamp out by turning each of the
adjustment screws ("1, 2, 3”) counterclockwise turn until the light is bright and
evenly distributed.
Please remember that a MSD 250/2 lamp is not a hot-restrike lamp therefore, you must wait
approximately 15 minutes before you can attempt to strike the lamp once it has been turned