CONNECTING TO MAINS TERMINAL

WARNING: This cooker must be

 

earthed.

 

 

 

 

 

 

 

Make connection as shown in Fig. 7 by

 

 

 

proceeding as follows:-

 

 

 

Preform wires to the appropriate shape to suit

 

 

 

fitting into the mains terminal block.

 

 

 

Strip inner insulation on wires using

 

 

 

wirestrippers.

 

 

 

Twist the bared wires using pliers.

 

 

 

Cut bared wires 10mm away from the end of

 

Fig.7

 

the inner insulation. Where uninsulated Earth

 

 

 

wires are used ensure they are suitably

 

 

 

sheathed to leave 10mm bare wire to fit into

 

 

 

the terminal.

 

 

 

Clamp bare wires into the relevant terminal and

 

 

 

check they are held by tugging each one in turn.

 

 

 

Clamp the mains cable securely ensuring 5mm

 

 

 

of the outer insulation is inside the terminal

 

 

 

block and that the wires are not taut but not so

 

 

 

slack as to cause any fouling. See Fig. 7.

 

 

 

Place fuse/miniature circuit breaker in circuit

 

 

 

and switch on at mains.

 

 

CONNECTING TO A HOB OR COOKER

 

 

POINT

 

 

 

Either follow in general terms the instructions

 

 

 

for connecting to the terminal block or refer to

 

 

 

the hob suppliers installation instructions.

 

 

 

 

 

 

 

Feed the cable through the cabinet and

 

 

 

arrange to route the cable away from

 

 

 

the cooker which may become hot.

 

 

 

 

 

 

CHECKING ELECTRICAL

 

 

CONNECTIONS

 

 

 

Correct electrical connection can be confirmed

 

 

 

when switching on the appliance as the timer

 

 

 

will be flashing.

 

 

NOTE: HOUSE CIRCUIT

 

 

Earth leakage and continuity tests must be carried

 

 

out before the cooker is connected to the mains

 

 

supply and re-checked after fitting.

 

 