electrolux 77

Electrical connection

The unit is preset to work with a voltage of single phase 230 V.

Before making the connection make sure that:

the energy power available in the user'shouseissufficientforthenormal supply of this appliance (see rating plate).

the unit is correctly connected to earth through a suitable plug and according to the installation country Laws.

the socket or the omnipolar switch usedfortheconnectionmustbeeasilv reached with the installed appliance.

The appliance is supplied with electric cable, therefore you will have to fit it with a standard plug, suitable for the total electric load shown on the rating plate. The plug isto be inserted into a suitable wall socket.

If you wish to directly connect to the mains, you have to interpose an omnipolar switch with a minimum opening between contacts of 3 mm, between the unit and the mains, complying with the existing regulations. The brown live wire (originating from the clamp of the cooker junction box) must always be connected to the phase of the mains supply. In any case, the supply cord must be positioned in such a way as it doesn't reach in any point a temperature higher by 50°C than the room temperature.

Should the supply cord need to be replaced, use only the following cable types:

H05RR-F / H05VV-F / H05V2V2-F (T90). It is necessary that the yellow/green earth wire is about 2cm longer than the live and neutral ones.

After the connection, test the heating elements for about 3 minutes to ensure that they are working correctly.

The manufacturer refuses any responsability in cases where normal safety measures are not observed.

Neutral wire

Phase

Ground (yellow - green)

Page 77
Image 77
Electrolux EKG 60111 user manual Electrical connection