Adaptation to different kinds of gas

To adapt the appliance to a different kind of gas from the one the appliance has been set for, follow the instructions below in their order.

Gas connection

LPG : use the rubber pipe holder «C».

Natural gas : use the pipe fitting «A».

Always insert the gasket «B». Then proceed with the gas connection, as indicated in the relevant paragraphs.

Hob burners nozzles replacement

-Remove the pan supports.

-Extract the caps and the wall baffles of the burners.

-Using a socket spanner 7 unscrew and remove the nozzles replacing them with the ones required for the kind of gas in use (see table "Burner characteristics").

Reassemble the parts following the same procedure backwards.

These burners do not need any primary air regulation.

Hob burners - Adjustment of minimum level

To adjust the minimum level:

1)turn the knob to the position of minimum flame;

2)remove the knob;

3a)when converting from natural gas to LPG, tightly screw the by-pass screw of the cocks;

electrolux 73

FO 2127

FO 0392

By-pass screw

Page 73
Image 73