Fig.7

4 Turn off the electricity supply and the thermostat; disconnect the pressure gauge and replace the test point plug . Turn on gas supply and check for gas soundness.

NOTE: The electrical supply must be connected in order to test the pressure.

Fig.7

INLET ELBOW

PRESSURE TEST POINT

4. RE-ASSEMBLE THE APPLIANCE

1 Re-fit the fascia panel. (See section A below).

A.REMOVAL OF FASCIA PANEL

1Remove the gas control knobs and timer control knobs.

2Remove the four screws (two each side) which are visible on the underside of the fascia. Fig.8.

3Tilt the bottom of the fascia panel out over. Withdraw the fascia panel by moving it down over to disengage it from the top fixing lugs.

4Replace in reverse order.

NOTE: To prevent the top fascia panel mounts becoming slack, it may be necessary to adjust the top fixing lugs.

Fig.8

39

Page 39
Image 39
Electrolux EOG9330 manual Re-Assemblethe Appliance, A.Removal Of Fascia Panel, Inlet Elbow Pressure Test Point