15
Electrolux 818 38 03-01/7
Installing the cabinet
When two appliances are placed beside each other,
the spacers enclosed in the plastic wrapping should
be glued betweenthe appliances. As shown in the
illustration.
Make surethat the power plug is not squashed or
damagedby the back of the product.
·A damaged power plug may overheat and cause a
fire.
Do not place heavy articles or the product i tself on
the power cord.
·there is a risk of a short circuit andfire.
If the power plug socket is loose, do not insert the
powerplug.
·there is a risk of electric shock or fire.
Toobtain the best performance fromthe cabinet,
ensure:
·the cabinet is placed in a dry, cool place and
is not exposed to directsunlight.
·the cabinet is not placed close to a s ource of
heat, e.g. a cooker or dishwasher.
·the cabinetis level. The cabinet should not lean
against any wall. If necessary adjust the
feet using theadjustment spanner supplied.
·there is good aircirculation around the cabinet
and that the air channelsbelow and behind
the cabinet arenot blocked. The ventilation
space abovethe cabinet must be at least 4 cm.
The ventilationspace can either be
a) directlyabove the cabinet, or
b) behind and above the top cupboard. In this case,
the space behind the cupboardmust be at least
50 mm deep.
Cabinet is placed at a location whos e ambient
temperaturecorresponds to the climate
classification*,for which the appliance is designed.
* See on the rating plate on the inside of the
appliance.
The following table shows which ambient
temperature is correct for each climate classification.
Climate
classification foran ambient temperature of
+10°C to +32°C
+16°C to +32°C
+18°C to +38°C
+18°C to +43°C
SN
N
ST
T
If the cabinet is placed in a corner and the si de with
the hinges facingthe wall, thedistance between the
wall and the cabinet must be at least 150 mm to
allow the door to openenough so that the baskets
can be removed.
The power plug must be accessible after in stallation
of the cabinet.
50mm
a
)
b
)
Electrical connection
Connect the cabinetto a grounded electrical outlet.
Voltage:230 V.
Fuse:10 A.
Referto therating plate on the left inside the
cabinet.