105
Preventive maintenance
Tomaintaincorrectandproperfunctioningandtopreventinterruptionof
service,thefollowingmaintenanceschemeshouldbeadheredto.
Themaintenanceintervalshouldbeadaptedtohowfrequentlythemachi-
ne is used.
Daily
• Checkthedooranddoorlock:
- Letthedoorremainopenandtrystartingthemachine.Themachine
should not start.
- Closethedoor,startthemachineandtryopeningthedoor.Itshould
not be possible to open the door until the drum has stopped turning.
- Checkthatthedoordoesnotleak.
- Cleanthedoorseal,removinganydetergentanduff.
• Checkthatthedrainvalvedoesnotleakduringthewashcycle.
• Cleanoutanydetergentremaininginthedetergentcompartment.Rapid
advance through a program and let the water rinse the compartment:
Every third month
May only be carried out by authorized personnel.
• Checkthatthedoordoesnotleak.
• Checkthedrainvalveandremoveanyuff.
• Inspecttheinteriorofthemachine(duringanactualwashcycletoen-
surethatnoleaksarenoticed)by:
- Turningofthemainpowerswitchofthemachine.
- Removethetopcoverandtheprotectivefrontandrearplates.
Preventive maintenance