48 Program unit
SHOW WEIGHT TIME, SEC.
Used for machines with weight count. Once weighing has been carried
out, the weight obtained is displayed over the specified time.
MAXDIFF,WASHTIMEMIN
Specify with the knob the maximum time deviation for the total time of the
wash program. If this is exceeded in comparison with the total time when
the same wash program was last used, the stored total time shall only be
adjusted with the limit time. Note that this applies to both positive and
negative time.
The time is given in minutes; 0 - 20
DEFAULTHEAT
Select whether the machine should be heated with steam (heating contac-
tors 1/2) or electricity (heating contactor 3) as the deerror heating system.
Yes = Electricity.
No = Steam.
BACKLIGHTTIMESEC.
Specify how long in seconds that the display lighting should be on without
the control knob being activated. The value 0000 means that the lighting is
on all the time.
OFFS.LEVELREADINGMM
ThevaluesetissubtractedfromtheACTUALvalueinmminordertocom-
pensate for the distance between the level recess and the bottom of the
inner drum. Once this has been set, the water level above the bottom of
the inner drum, etc. can be read.
DISPLAYWARNINGSEC.
Specify with the knob the number of seconds the warnings are to be dis-
played. Warnings are e.g. empty tank alarm from detergent that is shown
each time a wash program is displayed.
The time is given in steps of 1 second in the range 0 -255 seconds.