35
6204
18
19
6204
6204
20
21
6204
*SERVICE*
01.10.00.00
SHOW COM.PORTAR
WEIGHT CALIBRATION
MEASURE WEIGHT
MEASURE UNBALANCE
DISPLAY TEST
EXIT
*WEIGHT CALIBRATION*
YES
18
19 *SERVICE*
01.11.00.00
WEIGHT CALIBRATION
MEASURE WEIGHT
MEASURE UNBALANCE
DISPLAY TEST
EXIT
*START WEIGHING*
YES
20
21
Program unit
WEIGHTCALIBRATION
SelecttheWEIGHTCALIBRATIONrowand
press the knob.
• Operatethemachinewithanemptydrum.
• Afterweightcalibration,theweightdeviation
will be shown in a hexadecimal format on the
bottom line of the display.
• Thedrumwillgofasterandsloweranum-
ber of times during weight calibration. This
is normal. Weight calibration will take a few
minutes.
• Whenexitingweightcalibrationafteritis
complete, you will have the option of saving
the calibration value.
• Thevaluefor0calibrationistakenoneach
washing occasion and the weight value is
adjusted automatically for any deviations.
NOTE!
The drum must be empty during calibration.
Confirm that calibration is to be performed with
YESorreturntothepreviousmenuwithNO.
MEASURE WEIGHT
Select the MEASURE WEIGHT row and press
the knob.
Put in a known weight. The same weight must
be shown in the display once the weight has
been measured.
Confirm that measurement is to be performed
withYESorreturntothepreviousmenuwith
NO.
This function is used to check that the machine
is weighing correctly.