42 Program unit
TEMPCONTROLWATER
Select whether the machine is to control and adjust the water temperature
by opening and closing the main valves for hot and cold water during fil-
ling.
Yes = Control of main valves during filling.
- Alt.1: Hot and cold water valves both open. If the set water tem-
perature is exceeded, the hot water valve will be shut automati-
cally.
- Alt. 2: Only hot water valve open. If the set water temperature is
exceeded, the cold water valve opens automatically together with
the hot water valve.
No = No temperature control. The hot and cold water valves are both
open until the correct level has been attained.
SHOW °C
Select whether all the temperature values are to be displayed in °C or °F
Yes = All temperature values displayed in °C.
No = All temperature values displayed in °F.
DELAYEDSTART
Select whether there should be the possibility of setting a delay from when
the start button is pressed until the machine is to start.
Yes = Time for delayed start can be set. Delayed start is available as a se
parate menu bar in the start menu, where you can select the delay
in hours and minutes.
No = The delayed start function is disengaged.
AUTO RESTART
Select whether there should be the possibility of setting the machine for
automatic restart. Automatic restart is available as a separate menu in the
start menu, where the number of automatic restarts of the selected wash
programme can be selected by the user.
Yes = Number of automatic restarts can be set.
No = The delayed start function is disengaged.