75
1
5
6
E1-E3
K21
14
8
7 9 10 11
M1
234
12 13
3
Door and door lock
Thedoorlockunlocksthedoor
Theprogrammeunitrequestsdoorunlockingbyapplying0VoninputX92
ofthedoorlockcontroller.
Thefollowingcheckismadepriortounlockingofthedoor:
• No water in drum-input"Level"fromlevelguardB2isclosed=0V
• Drum not turning-pulsefrequencyoninput"Tacho"fromrotation
sensorB3islessthan0.4Hz.
Whentheaboveconditionsaremet,thedoorlockcontrolleroutputsan
openingpulseonoutputD0tothedoorlockactuator/coil,whichthen
unlocksthedoor.MicroswitchesS4aandS4bnowinterrupttheactuator/
doorlockandtheI/Ocard1relaysloseallvoltagetopreventthemotor
fromstarting(interlocksignalonmotorcontrollerinputX302).Thedrain
andwatervalvesofthemachinearenowdisabledandtheheaterandmo-
tor cannot be switched on.
1. ProgramunitA1
2. TemperaturesensorB1
3, LevelswitchB2
4, LevelswitchB4
5. DisplayA2
6. HeaterelementE1-3
7. MotorcontrolU1
8. RotationsensorB3
9. DoorlockmoduleA41
10. VoltageunitA5,PSU
11. I/Oboard
12. Watervalves
13. Drainvalve
14. Powersupply
3