50
DISPLAYSTATIST.SEC.
Indicate using the knob how long the statistics for COINS – HOUR COUN-
TER – PROGRAM COUNTER are to be displayed when the power to the
machine is switched on. The time is given in steps of 1 second in the range
0 -255 seconds.
SHOWSTAT.DOUBLECLI.
Indicate using the knob how long the statistics for COINS – HOUR COUN-
TER– PROGRAM COUNTER are to be displayed following rapidly pressing
the knob twice. The time is given in steps of 1 second in the range 0 -255
seconds.
LASTPROG.TIMEOUT(COIN)
After wash program ended and door opened, the used wash program will
be shown on the display for a certain time. This makes it possible for the
user to see the previous wash program that was selected and used.
When time ended the display will return to show the same as before the
power was cut.
SERVICEINTERVALHOUR
The machine can show an indication that service is needed on the display.
Select after how many hours the indication shall be shown after last reset
of the service indication.
NOTE!
Only used in CPUs with software for Freescale microprocessor S12
and in GEN6COINOP with software for Hitachi H8 microprocessor.
DRYCOM.PORTCPUand I/O
This is only used on machines with two different control systems such as
Compass and Selecta II.
Select which port on Compass to communicate with the Selecta II timer.
If"Dryercom.PortCPU"issettoYES,thecommunicationtothedryer
timer Selecta II will be done through the RS232 on CPU board. The internal
Communication RS232 port on the CPU for Compass will be used.
If "Dryer com. Port CPU" is set to NO, the communication to the Seleta II
timer can be done through the RS232 port available on I/O-boards. The
address to the I/O-board then needs to be set on the menu line "Dryer
com. Port I/O". If menu line set to zero, no communication accepted by
the Selecta II timer, will be performed on the I/O-board RS232 port.
NOTE!
Both menu lines can not be active at the same time.
The two menu lines are only valid in machines where the software for
the coin program selection interface is used.
Program unit