Initialization of the network settings

If the connection from the network is disabled due to destruction of the network settings or disremembering of the set value, reset the settings to the factory settings by using the following procedure and then redo the settings:

If the Presenter is in connection to the network, disconnect the Presenter from the network.

In the power supply OFF state, lower the [D] key of the DIP switch key on the backside of the Presenter to [1].

Turn ON the power supply, and wait for approx. 10 seconds.

Turn OFF the power supply, and return the [D] key of the DIP switch to [0].

Turn ON the power supply again. Then, the network settings and the FIP client settings are reset to the factory settings.

Note: Ensure that the [D] key of the DIP switch is returned to [0] after the initialization. If the key remains in the [1] position, the connection from the network is disabled.

Web server functions – Displaying quasi-moving images, displaying static image and operating remote control through the Web browser

When the Presenter is connected from the Web browser, quasi-moving images can be displayed, static images cab be displayed, and remote control can be operated. To connect the Presenter from the Web browser, enter the IP address or host name (if allocated) of the Presenter, following [http://], in the address column of the Web browser provided for entering the URL to be opened. Then, the HV-800SX/8000SX/ 8500SX page is displayed. Click the desired link there. Then, the selected function can be used.

Note: Even if the image is tried to be electronically magnified, rotated or frozen by operating this Presenter, the image output to the network is not affected by this operation.

- 39 -

Page 40
Image 40
Elmo HV-8000SX instruction manual Initialization of the network settings