Elmo HV-8000SX instruction manual Data format specifications

Models: HV-8000SX

1 56
Download 56 pages 12.28 Kb
Page 49
Image 49

Function

Command

Parameter

Data

Comments

 

 

 

 

 

 

 

 

 

Gamma switch

GM

(1.0)

 

 

 

 

 

Command to switch the gamma set value of

 

 

 

 

 

 

 

(0.9)

 

 

 

 

 

the image.

 

 

(0.8)

 

 

 

 

 

 

 

 

(0.7)

 

 

 

 

 

 

 

 

(0.6)

 

 

 

 

 

 

 

 

(0.5)

 

 

 

 

 

 

 

 

(0.4)

 

 

 

 

 

 

 

 

(0.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image rotation

RO

(OFF)

 

 

 

 

 

Command to rotate the image.

 

 

 

 

 

 

 

(90°)

 

 

 

 

 

 

 

 

(180°)

 

 

 

 

 

 

 

 

(270°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Aperture

AP

(OFF)

 

 

 

 

 

Command to switch the modulation

 

 

 

 

 

selection

 

(ON)

 

 

 

 

 

(edge emphasis) of the image.

 

 

 

 

 

 

 

 

 

White balance

AW

(OFF)

 

 

 

 

 

Command to switch the mode of the white

 

 

 

 

 

selection

 

(AUTO)

 

 

 

 

 

balance.

 

 

(ONE-PUSH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contrast

CT

(OFF)

 

 

 

 

 

Command to switch the contrast settings.

 

 

 

 

 

selection

 

(ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

DF

 

 

 

 

 

 

Command to reset to the initialized mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status request

QS

 

 

 

 

 

 

Command to inquire the status of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equipment.

 

 

 

 

 

 

 

 

 

ROM version

QR

 

 

 

 

 

 

Command to refer to the ROM version.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response data

SA

(OFF)

 

 

 

 

 

Command to select the presence of the

 

 

 

 

 

Selection1

 

(ON)

 

 

 

 

 

response to each operation command.

 

 

 

 

 

 

 

 

Default is ON.

 

 

 

 

 

 

 

 

 

Response data

SC

(OFF)

 

 

 

 

 

Command to add CR [0Dh] to the end of the

 

 

 

 

 

Selection 2

 

(ON)

 

 

 

 

 

response data. Default is OFF.

 

 

 

 

 

 

 

 

 

Note: " " in the data column means that SPACE [20H] should be transmitted twice.

Data format specifications

This command is executed in the form of 1-command/1 packet. The next command is not accepted until the previous processing is completed.

The communication command always starts with STX (Start of Text) , and ends with ETX (END of Text) .

If the communication format or command name is wrong, NAK (Negative Acknowledgement) will be sent from the Presenter as a result of failing to receive correctly.

When the communication format is correctly received, the Presenter sends ACK (Normal Acknowledgement) .

- 48 -

Page 49
Image 49
Elmo HV-8000SX instruction manual Data format specifications