Up to eight environmental units can be automatically and cen- trally controlled for emergency switching and to balance unit runtime. The AC3 controls two or three units. The RAC2-8 con- trols two through eight units and has the ability to provide alarm notification to pagers.







 

 

 

SiteScan Web is a monitoring solution for critical

 

 

 

 

 

environments that utilize a facility-view approach.

 

 

 

 

 

The system enables communications from Liebert

 

 

 

 

 

environmental and power units—as well as many

 

 

 

 

 

other pieces of analog or digital equipment to a front

 

 

 

 

 

end software package that provides monitoring, con-

 

 

 

 

 

trol and alarm management.

 

 

 

 

 

SiteScan monitoring gives you decision making

 

 

 

 

 

power to effectively manage the equipment that is



 

 

 

critical to your business. Designed with flexibility for

 

 

 



 

 

 

large, complex systems as well as smaller, single-site

 

 

 

 

 

 

 

 

facilities, the Liebert SiteScan line of products can

 

 

The Universal Moni-

provide real-time status and alarms.

 

 



 

 

tor keeps personnel

 

 

on-site and at remote

The microprocessor-based module provides two-way

 

 

locations apprised of

communication between an existing building man-

 

 

the status of equip-

agement system and up to 12 Liebert units via MOD-

 

 

ment through local

Bus or BACnet.

 

 

alarming and remote



 

 

paging services. The

 

 

panel will interface

OpenComms Nform centralizes the management of

 

 



with anything that

your distributed Liebert network equipment. Open-



closes an electrical

Comms Nform software solution combines full-scale

 

 

contact and any device

monitoring with the use of the existing network

with a 4-20mA signal. To improve process efficiency

infrastructure—so the cost of dedicated, out-of-band

and troubleshooting, the panel tracks data in an

communications cabling is eliminated. It is both scal-

alarm log, an event log and a trend log. The Univer-

able and adaptable so it can grow as your systems

sal Monitor has a local LCD interface and a remote

expand and needs change. OpenComms Nform will

dial-up interface.

 

 

 

monitor any Liebert SNMP device that supports a



 

 

 

network interface, such as the OpenComms Web

 

 

Zone detectors with

Card and the OpenComms Network Interface Card.

 

 

 

 

 

 

 

Authenticated alarm management and event notifi-

 

 

 

 

cable or single point

cation ensures that alarms are detected and acted

 

 

 

 

detectors provide

upon, which allows problems to be quickly resolved.

 

 

 

 

fast and accurate



 

 

 

 

indication of water in

 

 

 

 

you critical space.

The OpenComms Network Interface Card (OC-NIC)

 

 

 

 

 

 

 

 

These systems com-



 

 

 

and OpenComms Web Card (OC-Web Card) provide



 

 

municate with your

Ethernet connectivity for Liebert equipment. Operat-

unit or with a separate monitoring system. Area

ing status and alarms are communicated via the net-

water detection cable with distance measurement

work to external systems utilizing industry standard

and monitoring protects your entire room. This sys-

open protocols.

tem quickly and accurately calculates and displays



the location of water on the cable, allowing you to

The Environmental Discrete Outputs Card

promptly fin and correct a leak.



(ENV-DO) provides 16 discrete outputs, correspond-

ing to status and major alarm conditions. These

A seven-day temperature and

 

 

 

Form-C contact closures provide a straightforward

humidity recorder permits close

means to connect Liebert Environmental units to

examination of computer room

Building Management Systems (BMS), I/O or alarm

environment condition and can

panels.

be used as a permanent record



of the environmental control

 

 

 

 

system’s operation efficiency.

 

 

 

LEDs display customized alarm indication for any

The system includes pens, 100

dry contact input including alarms for Liebert envi-

recording charts; two bottles of recording ink (1 red

ronmental, power and UPS systems. The RCM4

ink and 1 blue ink).

monitors and displays four dry contact points.

 

