Emerson CF4600WB00 SW101 FAN/LIGHT WALL CONTROL SUPPLIED, Black Black White White Red, Stud

Models: CF4600GLZ00 CF4600WB00

1 20
Download 20 pages 6.5 Kb
Page 12
Image 12
SW101 FAN/LIGHT WALL

BP7306 Nottingham 6/19/06 1:00 PM Page 12

SW101 FAN/LIGHT WALL

CONTROL (SUPPLIED)

BLACK

TO (HOT)

120-

VOLT

SUPPLY

WHITE

GROUND BLACK

EMERSON

BLACK

TWO-CONDUCTOR BLACK

WHITE

WHITE

RED

TWO-CONDUCTOR

CABLE (WITH

GROUND)

GREEN WIRE (GROUND)

FROM HANGER BALL AND

HANGER BRACKET

Figure 15

BLUE FROM HANGER BALL AND WHITE

BLUE  WHITE BLACK

CEILING COVERBLUE

STUD (2) WHITE

Manual background HANGER BALL

Manual backgroundManual background 3. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Position the antenna wire on top of the receiver.

4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 14).

Manual backgroundManual background 5. Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 16).

Manual backgroundManual background 6. Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied) (Figure 16). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling.

CEILING COVER

Manual backgroundLOCKWASHER (2) 1-1/4" THREADED

STUD (2)

KNURLED

 

KNOB (2)

Figure 16

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

7.Your ceiling fan is now installed and wired and ready for use.

12

Page 12
Image 12
Emerson CF4600WB00, CF4600GLZ00 SW101 FAN/LIGHT WALL CONTROL SUPPLIED, BLACK TO HOT 120 VOLT SUPPLY WHITE GROUND, Stud