BP7306 Nottingham 6/19/06 1:00 PM Page 13
Setting Operating
Frequency of Wall
Control and Receiver
(Figure 17)
Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are
1. Slide the four switch levers in the wall control to your choice of ON (up) or down positions. Use a
2. In the receiver, slide the four switch levers to the same positions as set in the wall control. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate.
ANTENNA WIRE
ON
RECEIVER | CODE | WALL CONTROL | ||||
SWITCH | LEVERS |
|
| |||
4 | 3 | 2 | 1 | |||
|
| |||||
RECEIVER |
|
|
|
| ON | |
|
|
|
|
| ||
SWITCH LEVERS |
|
|
|
|
|
1 | 2 | 3 | 4 | CODE |
ON |
|
|
| SWITCH |
|
|
|
| |
WALL |
|
|
|
|
CONTROL |
|
|
|
Installation of Wall
Control
SINGLE-POLE INSTALLATION
(Figure 18)
HOT | BLK | FAN/LIGHT |
|
WALL CONTROL |
| ||
| EMERSON | BLACK |
|
|
| BLACK | LOAD |
NEUTRAL |
|
| GROUND |
|
|
| |
REMOTE CONTROL |
|
| |
RECEIVER LOCATED |
|
| |
WITHIN THE CEILING |
|
| |
COVER |
|
|
|
Figure 18
1. Disconnect power at circuit breaker or remove fuse.
2. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from control. Do not attempt to disconnect any wires not already connected to existing control.
3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.
!WARNING
Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.
4. Connect one black wire of wall control to the “hot” wire. Securely connect wires with wire connectors supplied (Figure 19).
Figure 17 | 5. Connect one black wire of wall switch |
| to the “load” (black) wire in wall box. |
| Securely connect wires with wire |
| connector supplied. |
13