Emerson CF4600WB00 Trouble Shooting, BP7306 Nottingham 6/19/06 1 00 PM Page, Air Comfort Products

Models: CF4600GLZ00 CF4600WB00

1 20
Download 20 pages 6.5 Kb
Page 20
Image 20
Trouble Shooting

BP7306 Nottingham 6/19/06 1:00 PM Page 20

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

 

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

 

1.

Fan will not

1. Fuse or circuit breaker

1.

Check main and branch circuit fuses

 

start.

 

blown.

 

or circuit breakers.

 

 

 

 

!

WARNING: Make sure main power

 

 

 

 

 

is turned off.

 

 

2.

Loose power line

2.

Check line power connections to fan.

 

 

 

connections to the fan, or

 

 

 

 

3.

Fan/Light Wall Control is OFF.

3.

Turn ON Fan/Light Wall Control.

 

 

4.

Code switches in remote control

4.

Check that both code switches

 

 

 

receiver and Fan/Light Wall Control

 

are set in the same positions.

 

 

 

are not set in the same position

 

 

 

 

 

 

2. Fan sounds

1. Blades not attached to fan.

1.

Attach blades to fan before

 

noisy.

 

 

 

operating.

 

 

2.

Screws securing fan blade

2.

Check to make sure the

 

 

 

flanges to mounting hub are

 

screws which attach the

 

 

 

loose.

 

blade flanges to the mounting

 

 

 

 

 

hub are tight.

 

 

3.

Wire connectors inside

3.

Check to make sure wire

 

 

 

switch cup rattling.

 

connectors in switch cup

 

 

 

 

 

are not rattling against each

 

 

 

 

 

other or against the interior

 

 

 

 

 

wall of the switch cup.

 

 

 

 

!

WARNING: Make sure main

 

 

 

 

 

power is turned off.

 

 

4.

Screws holding blades to

4.

Tighten screws securely.

 

 

 

flanges are loose.

 

 

 

 

5.

Loose screws in motor

5.

Check to make sure all

 

 

 

housing.

 

screws in motor housing

 

 

 

 

 

are snug (not over-tight).

 

 

 

 

 

3.

Fan wobbles

1. Setscrew in motor coupling

1.

Raise upper housing/glass and

 

excessively.

 

is not tightened securely.

 

coupling cover, then

 

 

 

 

 

tighten setscrew securely.

 

 

2.

Setscrew in the hanger ball/

2.

Tighten the setscrew in the

 

 

 

downrod assembly is loose.

 

hanger ball/downrod

 

 

 

 

 

assembly.

 

 

3.

Screws securing fan blade

3.

Check to be sure screws

 

 

 

flanges to mounting hub

 

which attach the fan blade

 

 

 

are loose.

 

flanges to the mounting hub

 

 

 

 

 

are tight.

 

 

4.

Fan blade flanges not

4.

Check to be sure that the

 

 

 

seated properly.

 

fan blade flanges seat firmly

 

 

 

 

 

and uniformly in the mounting

 

 

 

 

 

hub. If flanges are seated

 

 

 

 

 

incorrectly, loosen the flange

 

 

 

 

 

screws and retighten.

 

 

5.

Hanger bracket and/or

5.

Tighten the hanger bracket

 

 

 

ceiling outlet box is not

 

screws to the outlet box,

 

 

 

securely fastened.

 

and/or secure outlet box.

 

 

6.

Fan blades out of balance.

6.

Interchanging an adjacent

 

 

 

 

 

(side-by-side) blade pair can

 

 

 

 

 

redistribute the weight and

 

 

 

 

 

result in smoother operation.

 

 

 

 

 

Or use supplied balancing

 

 

 

 

 

kit to balance blades.

 

 

 

 

 

 

 

Air Comfort Products

 

Part No. F40BP73060001

DIVISION OF EMERSON ELECTRIC CO.

 

Printed in China 06/06

8100 W. Florissant ¥ St. Louis, MO 63136

Form No. BP7306-1

Page 20
Image 20
Emerson CF4600WB00, CF4600GLZ00 warranty Trouble Shooting, BP7306 Nottingham 6/19/06 1 00 PM Page, Air Comfort Products