BP7306 Nottingham 6/19/06 1:00 PM Page 20
!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
Trouble Shooting
| TROUBLE |
| PROBABLE CAUSE |
| SUGGESTED REMEDY |
|
|
|
|
| |
1. | Fan will not | 1. Fuse or circuit breaker | 1. | Check main and branch circuit fuses | |
| start. |
| blown. |
| or circuit breakers. |
|
|
|
| ! | WARNING: Make sure main power |
|
|
|
|
| is turned off. |
|
| 2. | Loose power line | 2. | Check line power connections to fan. |
|
|
| connections to the fan, or |
|
|
|
| 3. | Fan/Light Wall Control is OFF. | 3. | Turn ON Fan/Light Wall Control. |
|
| 4. | Code switches in remote control | 4. | Check that both code switches |
|
|
| receiver and Fan/Light Wall Control |
| are set in the same positions. |
|
|
| are not set in the same position |
|
|
|
|
|
| ||
2. Fan sounds | 1. Blades not attached to fan. | 1. | Attach blades to fan before | ||
| noisy. |
|
|
| operating. |
|
| 2. | Screws securing fan blade | 2. | Check to make sure the |
|
|
| flanges to mounting hub are |
| screws which attach the |
|
|
| loose. |
| blade flanges to the mounting |
|
|
|
|
| hub are tight. |
|
| 3. | Wire connectors inside | 3. | Check to make sure wire |
|
|
| switch cup rattling. |
| connectors in switch cup |
|
|
|
|
| are not rattling against each |
|
|
|
|
| other or against the interior |
|
|
|
|
| wall of the switch cup. |
|
|
|
| ! | WARNING: Make sure main |
|
|
|
|
| power is turned off. |
|
| 4. | Screws holding blades to | 4. | Tighten screws securely. |
|
|
| flanges are loose. |
|
|
|
| 5. | Loose screws in motor | 5. | Check to make sure all |
|
|
| housing. |
| screws in motor housing |
|
|
|
|
| are snug (not |
|
|
|
|
| |
3. | Fan wobbles | 1. Setscrew in motor coupling | 1. | Raise upper housing/glass and | |
| excessively. |
| is not tightened securely. |
| coupling cover, then |
|
|
|
|
| tighten setscrew securely. |
|
| 2. | Setscrew in the hanger ball/ | 2. | Tighten the setscrew in the |
|
|
| downrod assembly is loose. |
| hanger ball/downrod |
|
|
|
|
| assembly. |
|
| 3. | Screws securing fan blade | 3. | Check to be sure screws |
|
|
| flanges to mounting hub |
| which attach the fan blade |
|
|
| are loose. |
| flanges to the mounting hub |
|
|
|
|
| are tight. |
|
| 4. | Fan blade flanges not | 4. | Check to be sure that the |
|
|
| seated properly. |
| fan blade flanges seat firmly |
|
|
|
|
| and uniformly in the mounting |
|
|
|
|
| hub. If flanges are seated |
|
|
|
|
| incorrectly, loosen the flange |
|
|
|
|
| screws and retighten. |
|
| 5. | Hanger bracket and/or | 5. | Tighten the hanger bracket |
|
|
| ceiling outlet box is not |
| screws to the outlet box, |
|
|
| securely fastened. |
| and/or secure outlet box. |
|
| 6. | Fan blades out of balance. | 6. | Interchanging an adjacent |
|
|
|
|
| |
|
|
|
|
| redistribute the weight and |
|
|
|
|
| result in smoother operation. |
|
|
|
|
| Or use supplied balancing |
|
|
|
|
| kit to balance blades. |
|
|
|
|
|
|
| Air Comfort Products |
|
Part No. F40BP73060001 | DIVISION OF EMERSON ELECTRIC CO. |
|
Printed in China 06/06 | 8100 W. Florissant ¥ St. Louis, MO 63136 | Form No. |