![STANDARD WIRING FOR EXISTING 3-WAY CONTROL](/images/new-backgrounds/33541/3354129x1.webp)
BP7306 Nottingham 6/19/06 1:00 PM Page 15
STANDARD WIRING FOR EXISTING 3-WAY CONTROL
|
| EXISTING |
|
|
HOT | BLK | WALL CONTROL |
|
|
|
|
| ||
|
|
|
| BLACK |
| TRAVELER WIRES |
| LOAD | |
|
|
|
| |
| BLK | BLK |
| BLK |
HOT | BLK |
|
| |
|
|
| ||
| EMERSON |
| EMERSON | BLACK |
FAN/LIGHT |
|
| ||
|
|
| ||
WALL CONTROL | TRAVELER WIRES |
| LOAD | |
|
|
|
Figure 21
Operating Your
Ceiling Fan
4. To set the level of housing light brightness, press and hold the LIGHT button. The light brightness will continue to increase then decrease while the button is held down. When the light is at the desired brightness, release the button.
5. To turn the housing lights on and off, press and release the LIGHT button. The light will turn on at the light level previously set (see step 4).
6. If airflow is desired in the opposite direction, turn the fan off and wait for the blades to stop turning. Then slide the reversing switch to the opposite position (Figure 23) and turn the fan on again. The blades will turn in the opposite direction and reverse the airflow.
IMPORTANT
Fan installation must be completed, including the installation of the fan blades, before testing of the remote control.
Your Fan/Light Wall Control (Figure 22) has full control of your fan and light. However, airflow direction is controlled by a slide switch on the switch housing.
1. Restore electrical power to the outlet box by turning the electricity on at the service panel.
NOTE: Make sure that the ON/OFF slide switch on the Fan/Light Wall Control is in the ON position.
2. To set the desired fan speed, press the HI, MED, or LOW buttons to operate your fan on high, medium, or low speed (Figure 22).
3. To turn your fan off, press the OFF button.
Figure 22
REVERSING SWITCH
Figure 23
HI
LIGHT
MED
LOW
FAN OFF
EMERSON®
OFF |
|
| ON |
15