Emerson CF4600WB00, CF4600GLZ00 warranty Electrical Requirements

Models: CF4600GLZ00 CF4600WB00

1 20
Download 20 pages 6.5 Kb
Page 4
Image 4
Electrical Requirements

BP7306 Nottingham 6/19/06 1:00 PM Page 4

m. One loose parts bag containing:

1.Two 8-32 x 1-1/4” threaded studs

2.Two 8-32 x 1” threaded studs

3.Four knurled knobs

4.Four lockwashers

5.Five wire connectors

6.One clevis pin/hairpin clip assembly

7.Eleven 5-32 x 9/16” pan head screws

8.Sixteen 10-32 x 1/2” pan head screws

9.Sixteen #10 flat washers

10.One 5/16-18 x 1/4” setscrew

11.One hex wrench

12.Six 8-32 x 1/2” pan head screws

A

Manual background B

Manual background D

Manual background C

E Manual background F

G

H

Manual backgroundManual background 2. Remove the fan motor and housing assembly from the protective plastic bag. Place the fan assembly into the lower foam pad with the bottom of the motor facing up.

The lower foam pad serves as a holder for the fan during the first stages of assembly.

Electrical Requirements

IMPORTANT: Your ceiling fan will not function properly, and may be damaged, if used with any wall dimmer switch or control other than the Emerson Electric Fan/Light Wall Control supplied with the fan, or an optional Emerson Electric SR100 Remote Control.

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

Manual background IJ Manual background K

L

L Manual backgroundManual backgroundManual backgroundM

ON

EMERSON

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse or circuit breaker box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

4

Page 4
Image 4
Emerson CF4600WB00, CF4600GLZ00 warranty Electrical Requirements