UM1M820BNA User Instructions Issue AH, March 4, 2013 Spec No. 1M820BNA (Model M820B) Spec No. 1M820DNA (Model M820D) 90 Chapter 3. Local Display Menus
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
Figure 8 (cont’d from previous page, cont’d on next page) Local Menu Flow Diagrams
Manual
Man/AutoSet
PowerSystem
Rectifier
BattGroup
LVD
EIB
Converter
SMTemp
Note
Itemsmarked with an asterisk (*) can be changed
whilein Auto Mode. Beforeany other settings in
theManual submenus can be changed, you must
firstplace the controller into Manual Mode. U se
theMAN/AUTO SET menu to change the Controller
fromAuto Mode toM anualMode.
Whenyou return to Auto Mode, anyse ttingschanged
inManual Mode are returned to their previoussettin g
(settingbefore being placed in Manual Mode).
D
ENT
ENT
ENT
ENT
ENT
ENT
ESC
ESC
ESC
ESC
ESC
ESC
Auto/ManState
Auto (auto/ manual)
RelayOutput 1
Active (active/ not active)
...
RelayOutput 8
Active (active/not active)
ClrMtncRunTime
Yes
ENT
ECOMode
Enabled (disabled/ enabled)
BestOper Point
80% (30-90)
EnergySave Pt
45% (10-90)
FluctRange
10% (1-50)
CyclePeriod
168hour (1-8760)
RectsON Time
120min (0-255)
TurnOffDelay
5min (1-60)
C
ENT
ESC
ECOMode Man/AutoSet
PowerSystem
ToChange a Parameter:
Press or tomove up and
downlist of parameters.
PressENT to highlight selected parameter.
Press or tochange highlighted value.
PressENT to make the change.
PressESC to cancel the change.
Theparameter values shown in ( ) are the
adjustmentrange or acceptable values.
Factorydefault settings are listed in the
ACU+Configuration Drawing (C-dwg)
furnishedwith your system.
ToSelecta Sub-Menu:
Press or tomove cursor in
menuscreen (selects menu item).
PressENT to enter selected sub-menu.
ESC
ESC
LVD
LVDGroup
LVDUnit
ENT
LVD1Control
Connected (disconnected)
LVD2Control
Connected (disconnected)
LVDUnit
SMTemp
SMTempGroup
SMTemp1
SMTemp2
ENT
ESC
ESC
ConverterTrim
42.0V (42.0-58.0)
DCOn/Off Ctrl
SwitchOnAll (SwitchOffAll /SwitchOn All)
ConvLED Ctrl
StopFlashing (AllFlashing / Stop Flashing)
FanSpeed Ctrl
AutoSpeed (Full Speed / Auto Speed)
ConfirmID
Yes
ClearConv Lost
Clear
ClearComm Fail
Yes
ClrAllCommFail
Yes
AllConv Ctrl
DCOn/Off Ctrl
On (On/ Off)
OverVoltReset
On (On/ Off)
LEDControl
Cancel (Flash/ Cancel)
Conv#1
Converter
AllConv Ctrl
Conv#1
Conv#2
ENT
*
*
Rectifier
AllRect Ctrl
Rect#1
Rect#2
EQ/FLTControl
FloatCharge (equalize charge)
BattTestControl
Stop (start)
ResetBatt Cap
Yes
ClrBad Bat Alm
Yes
ClrLiBatt Lost
Clear
ClrLiBatComFail
Clear
ClrAbnlCurAlm
Yes
ClrCur Imb Alm
Yes
ClrBatTestFail
Yes
ENT ESC
ESC
RectifierTrim
53.9V (42.0-58.0)(21.0-29.0)
DCOn/Off Ctrl
SwitchOnAll (switchoff all)
ACOn/Off Ctrl
SwitchOnAll (switchoff all)
RectLED Ctrl
StopFlashing (allflashing)
FanSpeed Ctrl
AutoSpeed (full speed)
ConfirmID/PH
Yes
ClearRect Lost
Clear
ResetCycleAlm
Clear
ClearComm Fail
Yes
ENT
BattGroup
AllRect Ctrl
DCOn/Off Ctrl
On (on/ off)
ACOn/Off Ctrl
On (on/ off)
LEDControl
LEDControl (LEDcontrol / cancel)
RectifierReset
Reset
Rect#1
*
*
*
*
*
*
*
*
*
*
*
*
*
*
EIB1
RelayOutput 9
Active (active/not active)
RelayOutput 10
Active (active/not active)
RelayOutput 11
Active (active/not active)
RelayOutput 12
Active (active/not active)
RelayOutput 13
Active (active/not active)
ESC
EIB
EIB1
ENT
ESC
ENT
ENT
ESC
*
*
*
*
ENT
ESC
ESC
ClrSMTempLost
Clear *
SMTempGroup
ClrProbeAlm
Clear *
SMTemp1
ENT