Empire Comfort Systems DVD42FP3, DVD42FP5, DVD48FP5 Rear Vent Conversion, Special Vent Systems

Models: DVD48FP5 DVD36FP3 DVD42FP5 DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 DVD48FP3 DVD42FP3

1 52
Download 52 pages 60.93 Kb
Page 10
Image 10
REAR VENT CONVERSION

REAR VENT CONVERSION

VERTICAL VENTING

Note: Discard insulation

&retainer when venting off top of fireplace.

Note: Discard insulation

&retainer when using vertical venting off

HORIZONTAL VENTING

INLET VENT

SPECIAL VENT SYSTEMS COVER PLATE

Note: It is recommended that the

 

FLUE COVER PLATE

flue cover plate tab be pulled

 

 

 

outward prior to removal.

INLET VENT COLLAR

 

 

FLUE INSULATION

 

 

 

FLUE OUTLET

INSULATION

This will ensure that the plate

RETAINER

COLLAR

 

is not accidentally dropped

 

 

inside the rear air chamber.

 

 

FLUE COVER PLATE

(See note above) Simpson Duravent® GS 4" - 6 ⅝", refer to page 23

INLET VENT COVER PLATE

Converting flue take-off to rear venting

 

INLET VENT COLLAR

4.

Reinstall the inlet cover plate over the top inlet opening with 4

 

When switching out the flue and inlet vent collars to run horizontally

 

screws. See illustration above..

off the rear vent, the following steps must be taken.

5.

Install the flue collar assembly to the rear flue with 4 screws.

1. Remove the inlet vent collar (8 screws) and flue collar (4 screws)

6.

Install the inlet vent collar to the rear of the fireplace with 8

 

screws.

from the top of the fireplace, and set to the side.

 

7.

This completes the conversion for a rear vent application.

2. Remove the inlet cover plate and flue cover plate located on the

 

 

back of the fireplace. These will be used to close the top flue

 

Note: for top vented installations, the insulation and retainer are

and inlet openings.

 

to be removed from the flue pipe and discarded.

3. Insert the insulation retainer bracket and insulation into the top flue pipe before reinstalling the flue cover plate over the top flue with 4 screws.

SPECIAL VENT SYSTEMS

The following vent systems are acceptable for use with the DVD (32, 36, 42, 48)series fireplaces:

Simpson Duravent® GS 4" - 6 ⅝", refer to page 23

*American Metal Products 4" - 6 ⅝" *Selkirk Direct-Temp® 4" - 6 ⅝" *Security Secure Vent® 4" - 6 ⅝"

Empire Horizontal Round Termination Kit DVVK-4RE, refer to Page 27

Empire Flexvent Kit DVVK-4F, refer to page 30

*Can not be used in side wall horizontal vent installations in the State of Massachusetts.

Page 10

23552-1-0607

Page 10
Image 10
Empire Comfort Systems DVD42FP3 Rear Vent Conversion, Special Vent Systems, Simpson Duravent GS 4 - 6 ⅝, refer to page