Empire Comfort Systems DVD48FP3, DVD42FP5 Clearances, Locating Fireplace, Mantel Chart Figure

Models: DVD48FP5 DVD36FP3 DVD42FP5 DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 DVD48FP3 DVD42FP3

1 52
Download 52 pages 60.93 Kb
Page 8
Image 8
CLEARANCES

CLEARANCES

Clearance to Combustibles

Back

0" (0 mm)

Side

0" (0 mm)

Floor

0" (0 mm)

Top Stand-off

0" (0 mm)

Top Framing Edge

3" (76 mm)

SEE MANTLE CHART FOR

MAXIMUM MANTLE DEPTH

Mantel Chart (Figure 3)

12” (305mm)

 

10” (254mm)

 

 

MANTEL

 

 

8”

COMBUSTIBLE TRIM AND MANTELS

 

ALLOWED IN SHADED AREA

 

 

15”

6”

 

(381mm)

 

 

 

 

 

4 ½”

 

13 3/4”

3 3/4”

 

 

 

 

3”

 

 

2 1/4”

SEE MANTLE CHART FOR MINIMUM HEIGHT OF MANTLE ABOVE UNIT

FINISHED WALL (COMBUSTIBLE)

NON-COMBUSTIBLE FIRST 3(SEE MAGNIFIED VIEW)

2" x 4" HEADER

STAND OFF 3" (76 mm) HEIGHT ABOVE TOP OF FIREPLACE

3"

NAILING

FLANGES

11”

 

1 ½”

9”

 

 

 

8”

 

3/4”

7” 6”

 

 

 

5”

4”

3”

 

TOP EDGE OF FIREPLACE

Figure 3

Clearances (Figure 4)

Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6".

TOP FRAMING

LEDGE

GLASS FRONT

Figure 2

Combustible Material

No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles.

Note: When using Empire EMBF, UMC, and UMF Series Full Mantels with DVD32 and DVD36 Series Fireplaces, combustible clearance may be reduced to 1" clearance from top edge of fire- place face.

Figure 4

LOCATING FIREPLACE

Note: Island (C) and Room Divider

(D)installation is possible as long as the horizontal portion of the vent system (H) does not exceed 20 feet with a minimum vertical run of 8 feet. See details in Venting Section.

When you install your Direct Vent Fireplace in (D) Room divider or

(E)Flat on wall corner positions, a minimum of 6 inches clearance must be maintained from the perpendicular wall and the front edge of the appliance.

CORNER

CABINET

INSTALLATION

INSTALLATION

ISLAND

FLUSH WALL

INSTALLATION

INSTALLATION

ANGLED CORNER

 

INSTALLATION

ROOM DIVIDER

 

INSTALLATION

Figure 5

Page 8

23552-1-0607

Page 8
Image 8
Empire Comfort Systems DVD48FP3, DVD42FP5, DVD48FP5 Locating Fireplace, Mantel Chart Figure, Figure Clearances Figure