Positioning the Fireplace

 

A

 

CENTER

OF ELBOW

 

OUT

STRAIGHT

 

(MINIMUM)

Figure 23

MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE

FIREPLACE

HARD ELBOW DIMENSIONS

SERIES

"A"

"B"

"C"

DVD32FP

41-1/2"

4"

6" (152mm)

 

(1054mm)

(102mm)

 

DVD36FP

41-1/2"

4"

6"

 

(1054mm)

(102mm)

(152mm)

DVD42FP

43-1/2"

4"

6"

 

(1105mm)

(102mm)

(152mm)

DVD48FP

43-1/2"

4"

6"

 

(1105mm)

(102mm)

(152mm)

 

 

 

 

FIREPLACE

FLEX PIPE 90 DEGREE BEND

SERIES

"A"

"B"

"C"

DVD32FP

43"

4-1/2"

6-1/2"

 

(1092mm)

(114mm)

(165mm)

DVD36FP

43"

4-1/2"

6-1/2"

 

(1092mm)

(114mm)

(165mm)

DVD42FP

45"

4-1/2"

6-1/2"

 

(1143mm)

(114mm)

(165mm)

DVD48FP

45"

4-1/2"

6-1/2"

 

(1143mm)

(114mm)

(165mm)

Positioning the Fireplace

Determine the exact position of the appliance so the direct vent termination will be centered (if possible) between two (2) studs. This will avoid any extra framing. All vent kit pipes should be assembled on the unit after the unit is moved into the final position.

Cutting the Hole (Figures 23)

After the fireplace has been positioned in its permanent location, the hole through the exterior wall of the house can be cut. This hole must be 10" (254mm) high x 10" (254mm) wide with its center line determined by the amount of vertical rise and horizontal run of the termination. (See Figure

23)When locating the hole it must be noted that the bottom of the cap must be 12" (305mm) above the ground level, and top of the cap must be no less than 18" (457mm) below a combustible projection, and no closer than 9" (229mm) to any wall running parallel to vent termination. (See Figure 24)