Empire Comfort Systems Direct Ignition Lighting Instructions, Initial Start Up Gas Line Purge

Models: DVD48FP5 DVD36FP3 DVD42FP5 DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 DVD48FP3 DVD42FP3

1 52
Download 52 pages 60.93 Kb
Page 41
Image 41
DIRECT IGNITION LIGHTING INSTRUCTIONS

DIRECT IGNITION LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING WHAT TO DO IF YOU SMELL GAS

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electrical switch

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone.

Follow the gas supplier's instructions.

If you can not reach your gas supplier, call the fire department.

B.Use only the wall switch or remote control switch to turn the gas control on/off.Any attempted repairs or adjustments should be performed by a qualified service technician.Applying force or attempted repair may result in a fire or explosion.

C.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

 

 

 

 

LIGHTING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

STOP! Read the safety information above.

8.

Turn on all electric

 

power to the appliance.

 

2.

Turn off all electric power to the appliance.

9.

If the appliance will not operate, follow the instructions "TO

3.

This appliance is equipped with an ignition device that

 

TURN OFF GAS TO APPLIANCE," and call your service

 

 

automatically lights the burner. Do not try to light the burner

 

technician or gas supplier.

 

 

by hand.

 

 

 

 

 

4.Open bottom louver assembly, or open valve access door.

5.Turn gas line valve to "ON."

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "A"

in the safety information on reverse. If you do not smell gas,

 

go to the next step.

 

7. Close bottom louver assembly, or close hearth access plate.

ON

OFF

LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE TO TURN OFF GAS TO APPLIANCE

1.STOP! Read the safety information above.

2.Turn off all electric power to the appliance.

3.Open bottom louver assembly, or open the valve access door.

4.Turn gas line valve to "OFF."

5. Close bottom louver assembly, or close valve access door.

INITIAL START UP GAS LINE PURGE

NOTE: UNIT MUST BE PROPERLY GROUNDED FOR ELECTRONIC IGNITION TO FUNCTION.

On initial installation, or after extended periods where the fireplace has not been used, gas lines may require purging.

The installer or qualified service person may use the following purge procedures to prevent the delays that would be caused by waiting for the lockout periods between tries for ignition.

PURGE PROCEDURE

1.

Remove glass door and place away from the fireplace.

6.

Turn burner off and install glass door frame assembly.

2.

Turn on gas shut off valve. Follow ignition procedure.

7.

Test ignition of burner with glass door in place.

3.If burner does not light after spark sequence has ended, use an insulated jumper wire (see page 40) between terminal locations 12 and 13 for fast reset function.

4. Interrupt power for 5 seconds. The green indicator light will

INSULATED

JUMPER WIRE

blink 4 times repetitively. Then retry for ignition.

 

5.Allow time for any raw gas to dissipate and repeat steps 3 and 4 until ignition is achieved.