RF STANDING PILOT OPERATING INSTRUCTIONS

Features

Benefits

• Self powered millivolt receiver/valve

• No external power or batteries required to operate valve and flame modulation

• Thermostat performance

• Flame cycles and modulates such that heat output equals heat loss from the room

• Auto mode

• Flame & fan are controlled automatically

• Self powered millivolt control

• No external power required to control gas valve and flame modulation

• Integrated Valve Electronics

• No electronics, rheostat, or limit installation required

• Failure analysis

• Troubleshooting with information from LED

• Pilotstat interlock

• When valve is turned off, power unit must drop out before pilot can be relit

• F or C temperature units

• Display local temperature units

Please review and retain the instructions included with the RF Transmitter. It provides additional information and details concerning the operational procedures and functions for the RF Remote Control.

Functions

Flame powered system

Flame powered flame modulation

Electronics integrated into valve to provide thermostat, flame, and fan functions with RF commands

Temperature compensated RF receiver

Main burner goes to "high" when manual switch is set on "local"

Fan powered by 120 vac

Transmitter Signal

When the transmitter is in the Auto mode, a signal is sent every 10 minutes if there is a change in the room temperature

When the transmitter is in the On or Off modes, a signal is also sent every 10 minutes with the status of On or Off condition

The transmitter will work at a minimum of 25 feet from the receiver

Make sure antennae is not touching metal and is horizontal. Refer to Figure 84.

Receiver Shutdown of Burner

In the remote, auto mode the valve shuts off if it does not receive a signal within 3 hours from the transmitter

In the local mode the valve does not shut off

In the remote, manual mode the valve shuts off if it does not receive a signal within 6 hours from the transmitter

Thermopiles

The negative leads (white) must be connected to the terminals with the one white dot marked next to them

Each thermopile must provide at least 500 mV open circuit voltage

If output is erratic, check thermopile for intermittent shorts

LED Troubleshooting

Note: In normal operation, LED blinks once every two seconds; also, LED will be on for one second after every valid command received by the RV8310D; these are not error codes.

Failure codes (see Table) can occur anytime after the pilot burner is lit. Failure code timing is 1/4 second on, 1/2 second off. Sequence is failure code followed by LED not blinking for four seconds.

In the event of multiple failure codes, the next failure code follows the previous failure code by approximately three seconds.

Code Service Action

8Replace valve

7Confirm stepper motor connection exists

4Fuel conversion plug missing or has poor connection (RV8310E only)

3 Replace thermopile with Q313

2 Device too hot. Check application

1 None required. This is normal operation and indicates the control is powered

Page 58

21759-6-0608

Page 58
Image 58
Empire Comfort Systems P)-2, DVP42FP installation instructions RF Standing Pilot Operating Instructions

DVP42FP, P)-2 specifications

Empire Comfort Systems has established itself as a leader in the heating and venting industry, providing innovative solutions that cater to modern home heating needs. One of their standout products is the Empire Comfort Systems DVP42FP,P)-2, a direct vent gas fireplace that seamlessly combines aesthetics, efficiency, and technology.

At the heart of the DVP42FP,P)-2 is its contemporary design, which enhances the ambiance of any living space. With a sleek glass front and a range of stylish finishes, this fireplace serves as a perfect centerpiece, embodying both function and fashion. The generous viewing area allows for an unobstructed view of the mesmerizing flames, creating a cozy atmosphere in any room.

This fireplace is engineered for efficiency and performance. With an impressive heating output, the DVP42FP,P)-2 can effectively warm spaces while consuming minimal fuel. It boasts a high-efficiency rating, ensuring that homeowners can enjoy the warmth without incurring high energy costs. The direct vent technology allows for a sealed combustion system that draws air from outside while expelling exhaust gases directly outdoors. This ensures that the air quality inside the home is maintained while providing optimal heating performance.

Ease of use is another hallmark of the DVP42FP,P)-2. It features an intuitive remote control system, allowing users to adjust the temperature and flame settings conveniently from anywhere in the room. This level of user-friendly control enhances the overall experience, making it easy to create the perfect environment.

Another notable characteristic of this model is its safety features. Equipped with safety screens and an auto shut-off feature, the DVP42FP,P)-2 is designed to offer peace of mind, allowing families to enjoy their fireplace without worries about safety.

Maintenance is straightforward with the DVP42FP,P)-2, thanks to its accessible design. Regular upkeep is minimal, allowing homeowners to spend more time enjoying the warmth and beauty of their fireplace rather than worrying about system maintenance.

In conclusion, the Empire Comfort Systems DVP42FP,P)-2 is a captivating, efficient, and technologically advanced direct vent gas fireplace. With its modern design, high efficiency, user-friendly controls, and robust safety features, it represents a wise investment for anyone looking to enhance their home's comfort and aesthetic appeal. Whether for a new build or a renovation, this fireplace stands out as a premier choice for discerning homeowners.