Empire Comfort Systems P)-2, DVP42FP Locating Fireplace, Figure Clearances Figure

Models: DVP42FP P)-2

1 72
Download 72 pages 3.7 Kb
Page 8
Image 8
CLEARANCES

CLEARANCES

Clearance to Combustibles

Back

0" (0 mm)

Side

0" (0 mm)

Floor

0" (0 mm)

Top Stand-off

0" (0 mm)

Top Framing Edge

3" (76 mm)

Mantel Chart (Figure 3)

12” (305mm)

10” (254mm)

 

MANTEL

 

8”

COMBUSTIBLE TRIM AND MANTELS

ALLOWED IN SHADED AREA

 

15”6” (381mm)

4 ½”

13 3/4”

3 3/4”

SEE MANTLE CHART FOR

MAXIMUM MANTLE DEPTH

 

3”

11”

2 1/4”

1 ½”

9”

 

8”

3/4”

7”

6”

SEE MANTLE CHART FOR MINIMUM HEIGHT OF MANTLE ABOVE UNIT

FINISHED WALL (COMBUSTIBLE)

NON-COMBUSTIBLE FIRST 3(SEE MAGNIFIED VIEW)

TOP FRAMING

LEDGE

GLASS FRONT

2" x 4" HEADER

STAND OFF 3" (76 mm) HEIGHT ABOVE TOP OF FIREPLACE

3"

NAILING

FLANGES

5”

4”

3”

 

TOP EDGE OF FIREPLACE

Figure 3

Clearances (Figure 4)

Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6".

(914mm) Figure 3

Figure 2

Combustible Material

No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles.

Figure 4

Note: Island (C) and Room Divider

(D)installation is possible as long as the horizontal portion of the vent system (H) does not exceed 20 feet with a minimum vertical run of 8 feet. See details in Venting Section.

When you install your Direct Vent Fireplace in (D) Room divider or

(E)Flat on wall corner positions, a minimum of 6 inches clearance must be maintained from the perpendicular wall and the front edge of the appliance.

LOCATING FIREPLACE

CORNER

CABINET

INSTALLATION

INSTALLATION

ISLAND

FLUSH WALL

INSTALLATION

INSTALLATION

ANGLED CORNER

 

INSTALLATION

ROOM DIVIDER

 

INSTALLATION

Figure 5

Page 8

21759-6-0608

Page 8
Image 8
Empire Comfort Systems P)-2, DVP42FP Locating Fireplace, Figure Clearances Figure, Figure Combustible Material