 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (cont.)

Sealing 4” (102mm) Diameter Flue Outlet Tube DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (cont.) Manual background

VINYL SIDING KIT DV822

OUTSIDE MOUNTING PLATE

MEASURE

OUTSIDE WALL

Figure 46

EXT. WALL

SURFACE OR

VINYL SIDING KIT

FLUE

PIPE

CUT 2 ½” BEYOND

EXTERNAL WALL

SURFACE OR VINYL

SIDING KIT.

7.Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168mm) diameter tube from the opposite end. Do not crimp or enlarge tube.

8.Attach the 4” (102mm) diameter flue outlet tube onto the rigid venting system or directly to fireplace. Ensure the 4” (102mm) diameter flue outlet tube is placed as far as possible onto the rigid venting system. Mark the 4” (102mm) diameter flue outlet tube 2 1/2” (64mm) beyond the vinyl siding kit or wall. See Figure

46.Remove the 4” (102mm) diameter flue outlet tube from rigid venting system. When installing directly to fireplace, tape gasket needs to be used.

9.Mark or wrap tape completely around the tubes at the marked points to help in making a true cut. Do not crimp or enlarge tubes.

10.From outside: Push the 6 5/8” (168mm) diameter inlet tube/mount- ing plate onto end of rigid venting system to correct position. Fasten the outside mounting plate to the vinyl siding kit or wall with (4)

10x 1 1/2” screws. (Ensure upward slope).

11.From inside: Attach the inlet tube to the collar on the back of the fireplace (or the rigid venting system) using (3) self tapping screws.

12.Seal the 4” (102mm) diameter flue outlet tube. Follow instructions and diagram (Figure 48).

13.Fasten 4” (102mm) diameter flue outlet tube in place. Do not “twist” the flue outlet tube into the fireplace collar (or rigid venting sys- tem). Hold the tube by the seam and push in using a perpendicular “rocking” motion. This ensures the seam on the tube stay intact.

14.Fasten vent cap end using (3) 10 x 1/2” screws to mounting plate.

Sealing 4” (102mm) Diameter Flue Outlet Tube

Figure 47

DO NOT PLACE

OVERLAPPED

SECTION OVER

THE SEAM IN THE TUBE

VENT CAP END

APPLY SEALANT

ON THE INSIDE

1”

Figure 48

Note: Tape gasket to be applied prior to installing to fireplace flue outlet tube only. Tape gasket should not be used when mating the flue outlet tube to a rigid venting system.