The HBAnyware Utility User Manual Page 118
SAN Management Workstation Does Not
Have a Fibre Channel Connection. The
SAN management workstation does not
have a physical Fibre Channel connection
into the SAN because the other management
tools are all out-of-band. Can HBAnyware be
run on this SAN management workstation?
HBAnyware can communicate with remote HBAs using out-of-
band access as long as the remote host is running HBAnyware
and the remote server.
To solve this problem:
1. Start HBAnyware.
2. From the Main menu, select Discovery/Out-of-Band/Add
Host. The Add Remote Host dialog box appears.
3. In the Add Remote Host dialog box, enter either the name or
the IP-address of the host and click OK. When the selected
host is discovered, that host and any HBAs running on it will
be displayed in the discovery tree.
Cannot See New LUNs. Although new
LUNs were created on the storage array,
they do not appear in HBAnyware.
Refresh the screen.
The HBAnyware Security Configurator
(Security Configurator) software package
will not install. An error message states that
the latest version of the HBAnyware utility
must be installed first.
The system either has no HBAnyware software installed or has
an older version of the HBAnyware software installed. In either
case, obtain the latest version of the HBAnyware software and
follow the installation instructions. Remember to install the
HBAnyware software before installing the Security Configurator
package.
Cannot access formerly accessible
servers via the Security Configurator or
the HBAnyware utility.
This is actually a symptom of two different problems.
• New Keys Were Generated While Servers Were Offline
• Security Removed While Servers Were Offline
See Table19 on page 129 for details regarding these problems.
Cannot run the Security Configurator on a
system that is configured for only secure
access. I cannot run the Security
Configurator on a system that is configured
for only secure server access (it has no client
privileges). The following message is
displayed when the Security Configurator
starts: “This system is not allowed client
access to remote servers. This program will
exit.”
You cannot run the Security Configurator on a system that is
configured for only secure server access. Click OK to close the
message and the Configurator stops.
Table 11: General Situations (Continued)
Situation Resolution