The HBAnyware Utility User Manual Page 79All lpfc dynamic parameters are read/write using sysfs.Table 7: Driver for Linux, LPFC Dynamic Parameters (Do not require a driver reload to change)
Variable Default Min Max Comments
lpfc_discovery_min_wait*3 0 60 The minimum number of
seconds the driver waits for
the discovery to complete.
lpfc_discovery_wait_limit*600 0 600
(special
value
meaning
no limit)
The maximum number of
seconds the driver waits for
the discovery to complete.
lpfc_linkup_wait_limit*15 0 60 The number of seconds the
driver waits for the link to
come up.
lpfc_log_verbose 0x0 0x0 0xffff (bit mask) Extra activity
logging.
lpfc_nodev_tmo 30 0 255 Seconds to hold I/O err if
device disappears.
lpfc_use_adisc 0 0=Off 1=On Send ADISC instead of
PLOGI for device discovery
or RSCN.
Table 8: LPFCDFCDriver for Linux, Static Parameters
Variable Default Min Max Comments
lpfc_scsi_req_tmo 30 0 255 Time out value (in seconds)
for SCSI request sent
through lpfcdfc module.
(Not available using
HBAnyware. Command line
only.)