4. Using a No. 2 Phillips screwdriver, attach the switch(es) to the tray by installing the 4 thread
forming screws (6-32 x 1/4 100°) into the aligned holes.
5. Turn the tray over with the attached switch(es) now on the top of the tray.
Install the tray with the switch(es) attached into a rack following the instructions provided with the rack
mount kit.
UL Guidelines for Mounting Equipment in a Rack
When installing equipment in a rack, give careful consideration to the following factors:
The operating ambient temperature of rack-mounted equipment must not exceed the maximum
rated ambient temperature, which is indicated in this installation guide. (See “Operating
Conditions” on page 61.)
The air flow clearances specified in this installation guide must be maintained within the rack.
(See “Operating Conditions” on page 61.)
The AC supply circuit for rack-mounted equipment must be capable of supplying the total current
specified on all the labels of the rack-mounted equipment.
All AC power supply connections must be properly earthed. To ensure the integrity of the earth
connection, special attention must be given to connections that are not directly connected to the
branch circuit (for example, power strips).
The rack-mounting hardware has been carefully selected to properly support the equipment.
Any alternate rack-mounting hardware must provide equal or superior support.
Note: While there are eight holes on each side of the tray, only the four holes indicated on
each side of the tray in Figure 2-1 should be used for the switch.
Figure 2-1: Diagram Depicting Switch Installation into Tray (Note: Switches and tray are displayed
upside-down to facilitate proper installation.)