INSPEED™ SAN STORAGE SWITCH MODEL 355 APPENDIX A SPECIFICATIONS
USERS GUIDE
61
APPENDIX A Specifications

SWITCH SPECIFICATIONS

OPERATING CONDITIONS

The switch must be operated in a clean, dry environment with unrestricted airflow. Air flows in through
the cosmetic end and out through the business end (sometimes called the transceiver end or
“back-of-box”).
To avoid overheating, maintain a minimum clearance of two inches (50.8 millimeters) on each end of the
switch (the cosmetic end and the business end). Allow an adequate amount of space on the top and
sides of the switch for proper air ventilation. Do not place the switch on heat-generating surfaces.
Operating conditions are listed below.
Number of Ports 12
Operating Rate All ports operate at 1.0625 or 2.125 Gbps (selectable)
Port Media Type SFP
Enclosure 1U half-rack form-factor
Management Interface RS-232 or 10/100 Ethernet
Operating Mode Switching or Non-switching modes
Configurability Management interface configurable
Power On Selftest (POST) Yes
Dimensions 8.50 x 1.57 x 16.00 (W x H x D)
AC Power Input 50 or 60 Hz / 100 – 250 VAC / 0.6 – 0.4 A
AC Power Connector IEC connector
Weight Approximately 7 lbs.
Requirement Value
Operating Temperature 0°C to 40°C normal operation (ambient air temperature)
Storage -40°C to 80°C non-condensing
Power 50 or 60 Hz / 100 – 250 VAC / 0.6 – 0.4 A