INSPEED™ SAN STORAGE SWITCH MODEL 355

APPENDIX C EVENT MESSAGES

USERS GUIDE

 

APPENDIX C Event Messages

The event messages for the switch are listed below. For explanations, contact a customer service representative. The message’s applicable severity level as defined below is also provided.

Severity

Severity

Description

Level

 

 

 

 

 

1

EMERG

Immediate action required; system failing

 

 

 

2

ALERT

Unrecoverable condition reported; major event in progress

 

 

 

3

CRIT

Event failed with possible loss of integrity

 

 

 

4

ERR

Condition failed; action required

 

 

 

5

WRN

Failed event occurred; no action required

 

 

 

6

NOTIFY

Configuration error or abnormal event occurred; no action required

 

 

 

7

INFO

Event occurred; no action required

 

 

 

These severity levels can be used to designate which events trigger trap messages. Use the Command Line Interface (CLI) to designate the minimum severity level of events to be logged in the Event Log and at which severity level to illuminate the switch’s Fault LED.

Event

Event Message

Severity

 

 

 

1

Message log cleared

INFO

 

 

 

5

Power Supply 1 Failed

ALERT

 

 

 

6

Power Supply 1 Online

NOTIFY

 

 

 

9

Fan has stopped

EMERG

 

 

 

10

Fan has returned

ALERT

 

 

 

19

Temperatures over limit

ALERT

 

 

 

20

Temperature OK

INFO

 

 

 

50

SPF Overvoltage

EMERG

 

 

 

54

SOC has detected a CRC error in the EEPROM

NOTIFY

 

 

 

70

PORT # bypassed

NOTIFY

 

 

 

71

PORT # inserted

NOTIFY

 

 

 

72

Transceiver detected at port #

NOTIFY

 

 

 

73

Transceiver removed at port #

NOTIFY

 

 

 

74

SEOC occurred on PORT #

NOTIFY

 

 

 

75

Port exceeded OS threshold

NOTIFY

 

 

 

76

Port exceeded CRC threshold

NOTIFY

 

 

 

77

Loop UP on Port #

NOTIFY

 

 

 

78

Loop DOWN on Port #

NOTIFY

 

 

 

79

PORT received a LIP(F8)

WRN

 

 

 

80

PORT CRC Error detected in frame

WRN

 

 

 

81

PORT did not receive LIPF7) within timeout

WRN

 

 

 

65

Page 68
Image 68
Emulex 355 manual Severity Description Level, Event Event Message Severity

355 specifications

The Emulex 355 is a high-performance network interface card (NIC) designed specifically for data centers requiring advanced connectivity, reliability, and speed. With the rapid evolution of data transmission technology, the Emulex 355 stands out due to its robust features and capabilities that cater to the demands of modern IT infrastructures.

One of the key features of the Emulex 355 is its support for 10 Gigabit Ethernet, which allows for significantly faster data transfer rates compared to standard Gigabit connections. This increased bandwidth is essential for handling large volumes of data traffic, particularly in virtualized environments and cloud computing applications. Its high throughput ensures that data can be transmitted rapidly across networks, minimizing latency and improving overall performance.

The Emulex 355 employs advanced technologies such as iSCSI Offload and FCoE (Fibre Channel over Ethernet), which help enhance data processing efficiency. These technologies allow the card to offload processing tasks from the host system's CPU, reducing the load on server resources and optimizing performance. The result is a more efficient system that can handle more concurrent connections and processes without being overwhelmed.

In addition to speed and efficiency, reliability is paramount in data center operations. The Emulex 355 includes features like error detection and correction, ensuring data integrity during transmission. Built-in redundancy and failover capabilities safeguard against potential network disruptions, allowing for continuous availability of services—a crucial aspect in mission-critical environments.

The Emulex 355 also offers support for various robust networking protocols, enabling seamless integration into existing network infrastructures. Its compatibility with multiple operating systems and virtualization platforms, such as VMware and Microsoft Hyper-V, further enhances its versatility.

Another notable characteristic of the Emulex 355 is its energy-efficient design. It is optimized for lower power consumption without sacrificing performance, aligning with contemporary efforts to reduce the carbon footprint in data centers.

In conclusion, the Emulex 355 NIC is a powerful solution equipped with features that address the complex demands of modern data centers. Its combination of speed, reliability, and efficiency, along with advanced technologies, makes it a preferred choice for organizations looking to enhance their network capabilities and ensure smooth, uninterrupted operations.