Emulex 355 manual Troubleshooting Management Connections, Port Bypass Conditions and Recovery

Models: 355

1 74
Download 74 pages 23.77 Kb
Page 60
Image 60

INSPEED™ SAN STORAGE SWITCH MODEL 355

CHAPTER 4 TECHNICAL REFERENCE

USERS GUIDE

 

TROUBLESHOOTING MANAGEMENT CONNECTIONS

Problem

 

Recommended Action

 

 

 

Serial cable installed but

1)

Cycle power by reinstalling the power cord.

connection does not appear

2)

Check the terminal emulation program’s serial port parameters.

on terminal

3)

Replace the serial cable. (Make sure it is a null modem cable.)

 

 

 

Ethernet cable installed but

1)

Ensure a crossover ethernet cable is used (unless using an ethernet hub).

Web Manager does not

2)

Check the IP addresses on the switch and workstation as follows:

appear

At a command line prompt, type ping DNSorIP (where DNSorIP is the switch’s

 

DNS name or IP address) and press ENTER.

 

If a “Reply from…” or “...is alive...” message appears, the devices can

 

communicate.

 

If a “Request timed out” message appears (or the command times out), the

 

devices cannot communicate. Trace the cabling. If needed, reconnect the

 

devices.

 

 

 

PORT BYPASS CONDITIONS AND RECOVERY

Operational Condition

Recovery

 

 

Rx_los is asserted by an

The port stays bypassed until rx_los is de-asserted. At that time, the port

SFP/GBIC

insertion will be automatically retried. The port continues to stay bypassed until

 

the port can pass the port insertion criteria.

 

 

Tx_fault is asserted by an

The port stays bypassed until tx_fault is de-asserted. At that time, the port

SFP/GBIC

insertion will be automatically retried. The port continues to stay bypassed until

 

the port can pass the port insertion criteria.

 

 

F8 Failure notification is

The switch automatically tries to re-insert the device, by sending F7 Initialization

received by the port (when

notifications to the device connected to the bypassed port. The port continues to

the LIP F8 Recover policy is

stay bypassed until the device returns F7 Initialization notifications to the port

enabled)

and passes the port insertion criteria.

 

 

Loss of Sync (>100ms)

The port stays bypassed until a signal is re-established. At that time, the port

 

insertion will be automatically retried. The port continues to stay bypassed until

 

the port can pass the port insertion criteria.

 

 

Firmware Initiated

The port stays bypassed until the firmware sets the port control back to

 

automatic. At that time, the port insertion will be automatically retried. The port

 

continues to stay bypassed until the port can pass the port insertion criteria.

 

 

57

Page 60
Image 60
Emulex 355 Troubleshooting Management Connections, Port Bypass Conditions and Recovery, Operational Condition Recovery

355 specifications

The Emulex 355 is a high-performance network interface card (NIC) designed specifically for data centers requiring advanced connectivity, reliability, and speed. With the rapid evolution of data transmission technology, the Emulex 355 stands out due to its robust features and capabilities that cater to the demands of modern IT infrastructures.

One of the key features of the Emulex 355 is its support for 10 Gigabit Ethernet, which allows for significantly faster data transfer rates compared to standard Gigabit connections. This increased bandwidth is essential for handling large volumes of data traffic, particularly in virtualized environments and cloud computing applications. Its high throughput ensures that data can be transmitted rapidly across networks, minimizing latency and improving overall performance.

The Emulex 355 employs advanced technologies such as iSCSI Offload and FCoE (Fibre Channel over Ethernet), which help enhance data processing efficiency. These technologies allow the card to offload processing tasks from the host system's CPU, reducing the load on server resources and optimizing performance. The result is a more efficient system that can handle more concurrent connections and processes without being overwhelmed.

In addition to speed and efficiency, reliability is paramount in data center operations. The Emulex 355 includes features like error detection and correction, ensuring data integrity during transmission. Built-in redundancy and failover capabilities safeguard against potential network disruptions, allowing for continuous availability of services—a crucial aspect in mission-critical environments.

The Emulex 355 also offers support for various robust networking protocols, enabling seamless integration into existing network infrastructures. Its compatibility with multiple operating systems and virtualization platforms, such as VMware and Microsoft Hyper-V, further enhances its versatility.

Another notable characteristic of the Emulex 355 is its energy-efficient design. It is optimized for lower power consumption without sacrificing performance, aligning with contemporary efforts to reduce the carbon footprint in data centers.

In conclusion, the Emulex 355 NIC is a powerful solution equipped with features that address the complex demands of modern data centers. Its combination of speed, reliability, and efficiency, along with advanced technologies, makes it a preferred choice for organizations looking to enhance their network capabilities and ensure smooth, uninterrupted operations.